Abstract. Magnetic Resonance Imaging (MRI) is a medical tool that is used to form images of organs, soft tissues, bones and almost all internal body structures. The MRI image acquisition process takes a long time. One of the efforts to shorten the examination acquisition time is using the parallel imaging technique, namely SENSE. However, SENSE has a weakness, namely reducing the Signal Noise to Ratio (SNR). One of the denoising methods that can increase SNR is the Nonlocal mean filter (NLM). Post-image acquisition denoising becomes a cheaper and more effective alternative to use. The aim of this research is to measure the increase of SNR value in MRI SENSE images between before the denoising technique and after the denoising technique. This research is expected to produce a faster scanning time and maintain the quality of the MRI image. This experimental research was carried out by applying the SENSE parallel imaging technique to R-factors 2 and 4. The sequence used is T2WI TSE on axial slice phantom. The T2WI TSE SENSE phantom MRI image was corrected with the NLM denoising technique to produce a better quality image. Each variation is measured image information before and after the denoising technique. Image information is assessed quantitatively by measuring SNR. The results of the parametric test showed that there was an increase in the SNR value after the application of the denoising technique on the Phantom T2WI TSE SENSE MRI image at r-factor 2 and r-factor 4. The different test on the SNR assessment resulted in a p value < 0.001.

Publisher

Trans Tech Publications, Ltd.

Subject

Anesthesiology and Pain Medicine

Reference30 articles.

1. K. Somasundaram and P. Kalavathi, ORIENTAL JOURNAL OF Analysis of Imaging Artifacts in MR Brain Images,, (2012).

2. Improving Diagnostic Viewing of Medical Images using Enhancement Algorithms;Ahmed;Journal of Computer Science

3. D. Rochmayanti, T. S. Widodo, and I. Soesanti, Analisis Perubahan Parameter Number of Signals Averaged ( NSA ) Terhadap Peningkatan SNR dan Waktu Pencitraan pada MRI,, Jnteti, vol. 2, no. 4, p.37–45, (2013).

4. J. Westbrook C, Carolyne ,K Roth dan Talbot, MRI in Practice, Fourth Edi. United Kingdom: Blackwell Science Ltd, (2011).

5. G. W. Hashemi, H. Ray and Bradley, MRI : The Basic, Third. USA: Williams & Wilkins, (2010).

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3