CALIBRATION OF ANALYZERS OF THE MOBILE COMMUNICATION SYSTEM PARAMETERS

Author:

Meshcheriak Oleh, ,Velychko Oleh,

Abstract

The creation and operation of mobile communication systems is impossible without determining the parameters of base stations and mobile communication systems. For these purposes, appropriate devices are used that optimally combine testing capabilities in a single portable solution, which eliminates the need for several separate control and measuring devices. One of the main types of measurements of such devices is the measurement of the power of ultra-high and extremely high frequency signals. The article presents the method of calibrating meters of directional and absorbed power of ultra-high and extremely high frequency signals using the Bird 5000-EX mobile communication system parameter analyzers complete with the Power Sensor 5010V sensor and measuring sensors, Anritsu CellMaster MT8212EA and Arnitsu SiteMaster S331E spectrum analyzers. Calibration schemes for analyzers of parameters of mobile communication systems and analyzers of mobile communication base stations (hereinafter referred to as analyzers) have been developed. A measurement model of the analyzers based on the parameters of the directional and absorbed power of ultra-high and extremely high frequency signals based on the developed calibration schemes was created. The contribution of each component of the measurement model to the calibration result and the corresponding uncertainties of the model components were determined. The measurement uncertainty budget was made based on the proposed analyzer calibration model. The influence of the most significant influential values on the accuracy of measurement results was analyzed. The content of quantitative and qualitative indicators of corrections, which must be taken into account during calibration to achieve the highest accuracy of measurements, is revealed. The practical results of studies of measurement instability are given. The analyzer calibration method described in the article can be used in calibration laboratories that have the appropriate equipment and standards.

Publisher

Lviv Polytechnic National University

Subject

Automotive Engineering

Reference12 articles.

1. [1] Recommendation ITU-T G.811 (1997), Timing characteristics of primary reference clocks [Electronic resource]. - Available at: https://www.itu.int/rec/T-RECG.811-199709-I/en.

2. [2] Recommendation ITU-T G.811.1 (2017), Timing characteristics of enhanced primary reference clocks [Electronic resource]. - Available at: https://www.itu.int/rec/TREC-G.811.1-201708-I/en.

3. [3] Recommendation ITU-T G.812 (2004), Timing requirements of slave clocks suitable for use as node clocks in synchronization networks [Electronic resource]. - Available at: https://www.itu.int/rec/T-RECG.812-200406-I/en.

4. [4] EN ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. [Electronic resource]. - Available at: https://www.iso.org/ standard/66912.html

5. [5] EA-04/02. Evaluation of the Uncertainty of Measurement in Calibration. [Electronic resource]. - Available at: https://www.accredia.it/en/documento/ea-4-02-rev-03- evaluation-of-the-uncertainty-of-measurement-in-calibration/

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3