Reference values for airway resistance measured by the interrupter technique in preschool children

Author:

Demir Özek Gülcihan,Asilsoy Suna,Bak Mustafa,Maden Faize,Can Demet

Abstract

OBJECTIVE: In preschool children, diagnosis of asthma is difficult because of not using spirometry objectively. instead of spirometry, other techiques that not required sedation and cooperation to evaluate pulmonary functions. Interrupter technique that measures the resistance of the airway, is one of these methods. Insufficient of references values hamper the use of this technique commonly. In this study,to determine the referencesal values of Turkish preschool children for interrupter technique is intended. METHODS: 50 healthy children who applied between January 2008 and September 2008 to the Behcet Uz Children Hospital, were accepted for this study. During the expiratory phase of tidal breathing interrupter technique for airway resistance measurements were performed. At least 5 measurements were made for each case, and median values of these measurements were the base. References values were determined according to age and height. RESULTS: There were 28 boys (%56), 22 girls (%44); the average age is 3.2 ± 1.8 years respectively. The average value for Rint 0.489 kPa. L-1. s was determined.Rint values decrease with increasing age was observed (p <0.001). Rint value with the increase in height was found to be a significant reduction (p <0.001).Rint values will be calculated using the height parameter equation (Rint (e) = 1948-0015 × (cm)) was developed. CONCLUSION: Interrupter technique in preschool children with objective measurements of airway resistance will help in the diagnosis of asthma.Knowing reference values of healthy children may enable disseminated use of this tecnique.OBJECTIVE: In preschool children, diagnosis of asthma is difficult because of not using spirometry objectively. instead of spirometry, other techiques that not required sedation and cooperation to evaluate pulmonary functions. Interrupter technique that measures the resistance of the airway, is one of these methods. Insufficient of references values hamper the use of this technique commonly. In this study,to determine the referencesal values of Turkish preschool children for interrupter technique is intended. METHODS: 50 healthy children who applied between January 2008 and September 2008 to the Behcet Uz Children Hospital, were accepted for this study. During the expiratory phase of tidal breathing interrupter technique for airway resistance measurements were performed. At least 5 measurements were made for each case, and median values of these measurements were the base. References values were determined according to age and height. RESULTS: There were 28 boys (%56), 22 girls (%44); the average age is 3.2 ± 1.8 years respectively. The average value for Rint 0.489 kPa. L-1. s was determined.Rint values decrease with increasing age was observed (p <0.001). Rint value with the increase in height was found to be a significant reduction (p <0.001).Rint values will be calculated using the height parameter equation (Rint (e) = 1948-0015 × (cm)) was developed. CONCLUSION: Interrupter technique in preschool children with objective measurements of airway resistance will help in the diagnosis of asthma.Knowing reference values of healthy children may enable disseminated use of this tecnique.

Publisher

Galenos Yayinevi

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3