Positioning of Custom-Made Acetabular Components at Revision Hip Arthroplasty: Do They Really Match as “a key and a lock”?

Author:

Kovalenko A. N.1,Tikhilov R. M.2,Bilyk S. S.1,Shubnyakov I. I.1,Cherkasov M. A.1,Denisov A. O.1

Affiliation:

1. Russian Scientific Research Institute of Traumatology and Orthopedics named after R.R. Vreden

2. Russian Scientific Research Institute of Traumatology and Orthopedics named after R.R. Vreden; North-Western State Medical University named after I.I. Mechnikov, St. Petersburg

Abstract

Purposes are to determine1) what frequency and what degree is of custom acetabular implants malposition in comparison with planned position, 2) what the reason of malposition is and 3) what the malposition consequences we can wait for.Patients and methods. The observation group included 20 patients (18 women and 2 men) with severe ac-etabular defects. Mean age of patients made up 53 (22-72) years. Position of the implants was compared with the parameters of preoperative planning using 5 postoperative CT indices (inclination, anteversion of semi-spherical part of the implant, spatial location of the rotation center in three axes). More than 10° deviation for inclination or anteversion and 5° dislocation of the rotation center in any axis was considered as a malposition of the component.Results. Only 5 of 20 constructions matched conditionally permissible limits by all the parameters. Most often excessive dislocation of the rotation center in lateral direction (10 cases) and excessive anteversion (9 cases) were observed. During 6 weeks follow up no complications related to the acetabular component position were recorded.Conclusion. It was shown that at revision arthroplasty with custom-made implants the probability of implant malposition as compared to the preoperative plan. The main reason could be the complexity of intraoperative orientation under conditions of abnormal hip anatomy. Malposition of the implants beyond the stated values did not result in complications within the early postoperative period. The longer follow up is required for the assessment of the long-term results. 

Publisher

ECO-Vector LLC

Subject

General Medicine

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3