The Contribution of a Frequency-Compression Hearing Aid to Contralateral Cochlear Implant Performance

Author:

Perreau Ann E.,Bentler Ruth A.,Tyler Richard S.

Abstract

Background: Frequency-lowering signal processing in hearing aids has re-emerged as an option to improve audibility of the high frequencies by expanding the input bandwidth. Few studies have investigated the usefulness of the scheme as an option for bimodal users (i.e., combined use of a cochlear implant and a contralateral hearing aid). In this study, that question was posed. Purpose: The purposes of this study were (1) to determine if frequency compression was a better bimodal option than conventional amplification and (2) to determine the impact of a frequency-compression hearing aid on speech recognition abilities. Research Design: There were two separate experiments in this study. The first experiment investigated the contribution of a frequency-compression hearing aid to contralateral cochlear implant (CI) performance for localization and speech perception in noise. The second experiment assessed monaural consonant and vowel perception in quiet using the frequency-compression and conventional hearing aid without the use of a contralateral CI or hearing aid. Study Sample: Ten subjects fitted with a cochlear implant and hearing aid participated in the first experiment. Seventeen adult subjects with a cochlear implant and hearing aid or two hearing aids participated in the second experiment. To be included, subjects had to have a history of postlingual deafness, a moderate or moderate-to-severe hearing loss, and have not worn this type of frequency-lowering hearing aid previously. Data Collection and Analysis: In the first experiment, performance using the frequency-compression and conventional hearing aids was assessed on tests of sound localization, speech perception in a background of noise, and two self-report questionnaires. In the second experiment, consonant and vowel perception in quiet was assessed monaurally for the two conditions. In both experiments, subjects alternated daily between a frequency-compression and conventional hearing aid for 2 mo. The parameters of frequency compression were set individually for each subject, and audibility was measured for the frequency compression and conventional hearing aid programs by comparing estimations of the Speech Intelligibility Index (SII) using a modified algorithm (Bentler et al, 2011). In both experiments, the outcome measures were administered following the hearing aid fitting to assess performance at baseline and after 2 mo of use. Results: For this group of subjects, the results revealed no significant difference between the frequency-compression and conventional hearing aid on tests of localization and consonant recognition. Spondee-in-noise and vowel perception scores were significantly higher with the conventional hearing aid compared to the frequency-compression hearing aid after 2 mo of use. Conclusions: These results suggest that, for the subjects in this study, frequency compression is not a better bimodal option than conventional amplification. In addition, speech perception may be negatively influenced by frequency compression because formant frequencies are too severely compressed and can no longer be distinguished.

Publisher

Georg Thieme Verlag KG

Subject

Speech and Hearing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3