The Value of Electrically Evoked Stapedius Reflex in Determining the Maximum Comfort Level of a Cochlear Implant

Author:

de Andrade Kelly Cristina Lira1,Muniz Lilian Ferreira2,Menezes Pedro de Lemos1,Neto Silvio da Silva Caldas2,Carnaúba Aline Tenório Lins1,Leal Mariana de Carvalho2

Affiliation:

1. Universidade Estadual de Ciências da Saúde de Alagoas, Maceió, Brazil

2. Universidade Federal de Pernambuco, Recife, Brazil

Abstract

AbstractOne of the most important steps for good user performance with a cochlear implant (CI) is activation and programming, aimed at determining the dynamic range. In adults, current levels are determined by psychophysical measures. In babies, small children, or individuals with multiple disorders, this procedure requires techniques that may provide inconsistent responses because of auditory inexperience or the age of the child, making it a very difficult process that demands the collaboration of both the patient and the family.To study the relationship between the electrically evoked stapedius reflex threshold (ESRT) and maximum comfort level for stimulating electrodes (C-level) in postoperative CI users.Cross-sectional analytical observational case series study.We assessed 24 patients of both sexes, aged between 18 and 68 yr, submitted to CI surgery.Otoscopy and immittance. Next, an implant speech processor connected to an Itautec® computer containing the manufacturer’s software (custom sound Ep 3–2) was used, as well as an AT 235h probe inserted into the ear contralateral to the CI to capture the stapedius reflex, obtaining electrically evoked stapedius reflex thresholds.Data from the last programming, defining C-levels for each electrode studied, were extracted from the databank of each patient. The manual decay function of the AT 235h middle ear analyzer was used to observe ESRT response in a same window for a longer response capture time. Electrodes 22, 16, 11, 6, and 1 were tested when active, with the aim of using electrodes over the entire length of the CI, and ESRT was considered present when compliance was ≥0.05 ml. Stimuli, in current units, were always initiated at 20 cu above the C-level. The analysis of variance parametric test, Tukey’s honest significant difference test, the t-test, Wilcoxon nonparametric test, and the Kolmogorov–Smirnov test examined whether significant relationships existed between these other factors.The results demonstrate that all the electrodes selected for the study exhibited higher mean reflex threshold values than their mean C-level counterparts. However, there was no significant difference between them, for electrodes 1, 6, 11, and 16. The data provided allow the use of ESRT to define C-level values and make it possible to stipulate a correction factor ranging between 6 and 25.6 electrical units.The use of electrically evoked stapedius reflex thresholds can help the team in charge of programming CIs, making the process faster and safer, mainly for infants, small children, or individuals with multiple disorders.

Publisher

Georg Thieme Verlag KG

Subject

Speech and Hearing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3