Eustachian Tube Dysfunction and Wideband Absorbance Measurements at Tympanometric Peak Pressure and 0 daPa

Author:

Aithal Sreedevi12,Aithal Venkatesh12,Kei Joseph2,Anderson Shane3,Liebenberg Simon3

Affiliation:

1. Department of Audiology, The Townsville Hospital, Townsville, Australia

2. Research Unit for Children, School of Health, and Rehabilitation Sciences, University of Queensland, Faculty of Healthy Sciences, St. Lucia, Australia

3. Department of ENT, The Townsville Hospital, Townsville, Australia

Abstract

AbstractAlthough wideband absorbance (WBA) provides important information about middle ear function, there is limited research on the use of WBA to evaluate eustachian tube dysfunction (ETD). To date, WBA obtained under pressurized condition has not been used to evaluate ETD.The objective of the study was to compare WBA at 0 daPa and tympanometric peak pressure (TPP) conditions in healthy ears and ears with ETD.A cross-sectional study design was used.A total of 102 healthy ears from 79 participants (mean age = 10.0 yr) and 43 ears from 32 patients with ETD (mean age = 16.0 yr) were included in this cross-sectional study. WBA was measured at 0 daPa (WBA0) and TPP WBA at TPP (WBATPP).WBA results were analyzed using descriptive statistics and t-tests with the Bonferroni correction. An analysis of variance with repeated measures was applied to the data.WBA0 was significantly lower in the ETD group than in the control group. The WBA0 of the control group demonstrated a broad peak between 1.25 and 4 kHz, whereas the WBA0 of the ETD group had a peak between 2.5 and 4 kHz. WBATPP of the ETD group approached values close to that of the control group. In the control group, WBATPP was only 0.06 to 0.09 higher than WBA0, whereas in the ETD group, WBATPP was 0.29 to 0.42 higher than WBA0 between 0.6 and 1.5 kHz. A differential pattern of WBA at TPP relative to 0 daPa was observed between ears with ETD and ears with otitis media with effusion (OME) and negative middle ear pressure (NMEP).Hence, a comparison of WBA0 and WBATPP can provide potentially useful diagnostic information, and hence can be used as an adjunct tool to evaluate ETD. This is important especially in young children or some adults who are unable to perform maneuvers such as Toynbee or Valsalva during ETD assessment. Further research is needed to verify the results using test performance measures to determine whether WBA0 and WBATPP can objectively determine the presence of ETD or OME with NMEP.

Publisher

Georg Thieme Verlag KG

Subject

Speech and Hearing

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3