Development and Validation of a Portable Hearing Self-Testing System Based on a Notebook Personal Computer

Author:

Liu Yan,Yang Dong,Xiong Fen,Yu Lan,Ji Fei,Wang Qiu-Ju

Abstract

Background: Hearing loss affects more than 27 million people in mainland China. It would be helpful to develop a portable and self-testing audiometer for the timely detection of hearing loss so that the optimal clinical therapeutic schedule can be determined. Purpose: The objective of this study was to develop a software-based hearing self-testing system. Research Design: The software-based self-testing system consisted of a notebook computer, an external sound card, and a pair of 10-Ω insert earphones. The system could be used to test the hearing thresholds by individuals themselves in an interactive manner using software. The reliability and validity of the system at octave frequencies of 0.25 Hz to 8.0 kHz were analyzed in three series of experiments. Study Sample: Thirty-seven normal-hearing particpants (74 ears) were enrolled in experiment 1. Forty individuals (80 ears) with sensorineural hearing loss (SNHL) participated in experiment 2. Thirteen normal-hearing participants (26 ears) and 37 participants (74 ears) with SNHL were enrolled in experiment 3. Each participant was enrolled in only one of the three experiments. Data Collection and Analysis: In all experiments, pure-tone audiometry in a sound insulation room (standard test) was regarded as the gold standard. SPSS for Windows, version 17.0, was used for statistical analysis. The paired t-test was used to compare the hearing thresholds between the standard test and software-based self-testing (self-test) in experiments 1 and 2. In experiment 3 (main study), one-way analysis of variance and post hoc comparisons were used to compare the hearing thresholds among the standard test and two rounds of the self-test. Linear correlation analysis was carried out for the self-tests performed twice. The concordance was analyzed between the standard test and the self-test using the kappa method. p < 0.05 was considered statistically significant. Results: Experiments 1 and 2: The hearing thresholds determined by the two methods were not significantly different at frequencies of 250, 500, or 8000 Hz (p > 0.05) but were significantly different at frequencies of 1000, 2000, and 4000 Hz (p < 0.05), except for 1000 Hz in the right ear in experiment 2. Experiment 3: The hearing thresholds determined by the standard test and self-tests repeated twice were not significantly different at any frequency (p > 0.05). The overall sensitivity of the self-test method was 97.6%, and the specificity was 98.3%. The sensitivity was 97.6% and the specificity was 97% for the patients with SNHL. The self-test had significant concordance with the standard test (kappa value = 0.848, p < 0.001). Conclusions: This portable hearing self-testing system based on a notebook personal computer is a reliable and sensitive method for hearing threshold assessment and monitoring.

Publisher

Georg Thieme Verlag KG

Subject

Speech and Hearing

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3