Relationships among Standard and Wideband Measures of Middle Ear Function and Distortion Product Otoacoustic Emissions

Author:

Schairer Kim S.,Morrison Brooke,Szewczyk Ellyn,Fowler Cynthia G.

Abstract

Background: The overall goal of the current study was to examine the relationships among uncompensated admittance (Ya) at ambient pressure extracted from tympanograms, energy reflectance (ER) measures at ambient pressure from wideband acoustic transfer functions (WATF), and distortion product otoacoustic emissions (DPOAEs). If WATF measures of Ya are comparable to tympanometric measures of Ya at ambient pressure, it would be further evidence that the two systems provide comparable information at ambient pressure. Such a relationship could be used as a cross-check or validation for WATF measures and support the use of WATFs in lieu of tympanograms in some applications. Finally, if WATF measures of Ya and/or ER at DPOAE stimulus frequencies can account for some of the variability observed in DPOAE levels and/or signal-to-noise ratios (SNRs) in ears with normal hearing, the relationships could be used to improve hearing screening procedures. Purpose: The hypotheses were as follows: (1) measures of Ya at ambient pressure are significantly correlated as measured with tympanometric and WATF procedures and (2) measures of Ya and ER at DPOAE stimulus frequencies are significantly correlated with DPOAE level and SNR. Research Design: Repeated measures in human adults. Study Sample: Forty ears of 20 adults with normal hearing and middle ear function were included in the final sample. Data Collection and Analysis: Tympanograms were obtained using probe frequencies of 226, 678, and 1000 Hz; WATFs were obtained using a click probe, and DPOAEs were elicited with f2's of 1000, 2000, and 4000 Hz. A repeated measures analysis of variance (RM-ANOVA) was completed to identify significant differences between ears and among probe frequencies for Ya measured at ambient pressure from the Tympstar and for Ya measured at the three closest frequencies on the WATFs. Lines were fit to the comparison of Ya from the Tympstar and WATF, and percent variance accounted for (r2) was calculated. Ya and ER were extracted at all stimulus frequencies that were used to elicit DPOAEs and were compared to DPOAE levels and SNRs. RM-ANOVAs were completed to identify any significant differences in DPOAE level and SNR between ears and among f2 conditions. Lines were fit to the comparison of Ya and ER measures at f1 and f2 with the DPOAE levels and SNRs. The relationship between behavioral air conduction threshold at each f2 and DPOAE level (and SNR) was examined with regression analysis. Results: Ya was significantly correlated between the tympanometric and WATF measures at all three probe-tone frequencies. Ya and ER at f1 and f2 were significantly correlated with DPOAE level for f2 = 4000 Hz. Conclusions: The implications are as follows: (1) WATFs, which can be obtained with the same probe microphone system as DPOAEs, could be used as a supplement to tympanometry in a diagnostic test battery, and the relationship between Ya measured on the two systems could be used for verification, and (2) Ya and ER measures from WATFs at both DPOAE stimulus frequencies account for some of the variability observed in DPOAE levels at f2 = 4000 Hz in normal ears.

Publisher

Georg Thieme Verlag KG

Subject

Speech and Hearing

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3