Intrasubject Variability in Power Reflectance

Author:

Abur Defne,Horton Nicholas J.,Voss Susan E.

Abstract

Background: Power reflectance measurements are an active area of research related to the development of noninvasive middle-ear assessment methods. There are limited data related to test-retest measures of power reflectance. Purpose: This study investigates test-retest features of power reflectance, including comparisons of intrasubject versus intersubject variability and how ear-canal measurement location affects measurements. Research Design: Repeated measurements of power reflectance were made at about weekly intervals. The subjects returned for four to eight sessions. Measurements were made at three ear-canal locations: a deep insertion depth (with a foam plug flush at the entrance to the ear canal) and both 3 and 6 mm more lateral to this deep insertion. Study Sample: Repeated measurements on seven subjects are reported. All subjects were female, between 19 and 22 yr old, and enrolled at an undergraduate women’s college. Data Collection and Analysis: Measurements on both the right and left ears were made at three ear-canal locations during each of four to eight measurement sessions. Random-effects regression models were used for the analysis to account for repeated measures within subjects. The mean power reflectance for each position over all sessions was calculated for each subject. Results: The comparison of power reflectance from the left and right ears of an individual subject varied greatly over the seven subjects; the difference between the power reflectance measured on the left and that measured on the right was compared at 248 frequencies, and depending on the subject, the percentage of tested frequencies for which the left and right ears differed significantly ranged from 10% to 93% (some with left values greater than right values and others with the opposite pattern). Although the individual subjects showed left-right differences, the overall population generally did not show significant differences between the left and right ears. The mean power reflectance for each measurement position over all sessions depended on the location of the probe in the ear for frequencies of less than 1000 Hz. The standard deviation between subjects' mean power reflectance after controlling for ear (left or right) was found to be greater than the standard deviation within the individual subject’s mean power reflectance. The intrasubject standard deviation in power reflectance was smallest at the deepest insertion depths. Conclusions: All subjects had differences in power reflectance between their left and right ears at some frequencies; the percentage of frequencies at which differences occurred varied greatly across subjects. The intrasubject standard deviations were smallest for the deepest probe insertion depths, suggesting clinical measurements should be made with as deep an insertion as practically possible to minimize variability. This deep insertion will reduce both acoustic leaks and the effect of low-frequency ear-canal losses. The within-subject standard deviations were about half the magnitude of the overall standard deviations, quantifying the extent of intrasubject versus intersubject variability.

Publisher

Georg Thieme Verlag KG

Subject

Speech and Hearing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3