Restriction on Motion of Break Arcs Magnetically Blown-Out by Surrounding Walls in a 450VDC/10A Resistive Circuit

Author:

KATO Keisuke1,SEKIKAWA Junya1

Affiliation:

1. Graduate School of Engineering, Shizuoka University

Publisher

Institute of Electronics, Information and Communications Engineers (IEICE)

Subject

Electrical and Electronic Engineering,Electronic, Optical and Magnetic Materials

Reference10 articles.

1. [1] P.G. Slade, Electrical Contacts: Principles and Applications, Second Edition, CRC Press, 2013.

2. [2] P. Meckler, F. Gerdinand, R. Weiss, U. Boeke, and A. Mauder, “Hybrid switches in protective devices for low-voltage DC grids at com-mercial used buildings,” Proc. 27th International Conf. on Electrical Contacts, pp.120-125, Dresden, June 2014.

3. [3] H. Koepf, E.-D. Wilkening, C. Klosinski, and M. Kurrat, “Breaking performance of protection devices for automotive dc powertrainswith a voltage of 450 V,” Proc. 27th International Conf. on Electrical Contacts, pp.126-131, Dresden, June 2014.

4. [4] K. Yoshida, K. Sawa, K. Suzuki, and K. Takaya, “Influence of Nickel Content on Various Characteristics of AgNi Contacts for Electromagnetic Contactors,” Proc. 60th IEEE Holm Conf. on Electrical Contacts, pp.1-5, New Orleans, Oct. 2014.

5. [5] K. Sawa, M. Tsuruoka, and M. Morii, “Fundamental Characteristics of Arc Extinction by Magnetic Blow-out at DC Voltages (<500V),” Proc. 60th IEEE Holm Conf. on Electrical Contacts, pp.1-6, New Orleans, Oct. 2014.