Image-guided frameless stereotactic needle biopsy in awake patients without the use of rigid head fixation

Author:

Amin Devin V.,Lozanne Karl,Parry Phillip V.,Engh Johnathan A.,Seelman Kathleen,Mintz Arlan

Abstract

Object Image-guided frameless stereotactic techniques provide an alternative to traditional head-frame fixation in the performance of fine-needle biopsies. However, these techniques still require rigid head fixation, usually in the form of a head holder. The authors report on a series of fine-needle biopsies and brain abscess aspirations in which a frameless technique was used with a patient's head supported on a horseshoe headholder. To validate this technique, they performed an in vitro accuracy study. Methods Forty-eight patients underwent fine-needle biopsy of intracranial lesions that ranged in size from 0.9 to more than 107.7 ml; a fiducial-less, frameless, image-guided technique was used without rigid head fixation. In 1 of the 48 patients a cerebral abscess was drained. The accuracy study was performed with a skull phantom that was imaged with a CT scanner and tracked with a registration mask containing light-emitting diodes. The objective was a skin fiducial marker with a 4-mm circular target to accommodate the 2.5-mm biopsy needle. A series of 50 trials was conducted. Results Diagnostic tissue was obtained on the first attempt in 47 of 48 brain biopsy cases. In 2 cases small hemorrhages at the biopsy site were noted as a complication on the postoperative CT scan. One of these hemorrhages resulted in hand and arm weakness. The accuracy study demonstrated a 98% success rate of the biopsy needle passing through the 4-mm circular target using the registration mask as the registration and tracking device. This demonstrates a ± 0.75-mm tolerance on the targeting method. Conclusions The accuracy study demonstrated the ability of the mask to actively track the target and allow navigation to a 4-mm-diameter circular target with a 98% success rate. The frameless, pinless, fiducial-less technique described herein will likely be another safe, fast alternative to frame-based stereotactic techniques for fine-needle biopsy that avoids the potential morbidity of rigid head-pin fixation. Furthermore, it should lend itself to other image-guided applications such as the placement of ventricular catheters for shunting or Ommaya reservoirs.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

Cited by 29 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3