Anatomical feasibility of C-2 pedicle screw fixation: the effect of variable angle interpolation of axial CT scans

Author:

Burke Lauren M.,Yu Warren D.,Ho Anthony,Wagner Timothy,O'Brien Joseph R.

Abstract

Object Anatomical variability of the C-2 pedicle poses a challenge for C-2 fixation. The use of multidimensional CT scanning is not widely used but might be an asset to preoperative planning. Careful preoperative planning is imperative for instrumentation at C-2. Fine-cut, noncontrast CT scanning is a useful tool for delineating anatomy; however, the axis of the images is not always along the anatomical axis of the vertebra in question. The authors evaluated the suitability of C-2 pedicles for screw placement by using OsiriX (Pixmeo) software to change the gantry angle of CT angiograms to measure the anatomical dimensions of the C-2 pedicle. Methods The authors conducted a retrospective review of CT angiograms of the head and neck from 47 trauma patients seen consecutively at George Washington University Hospital. For each patient, 3 independent observers determined length and width of each C-2 pedicle (94 samples) by using OsiriX. OsiriX is a DICOM viewer that enables navigation and visualization in multidimensional imaging, such as 3D imaging, which was used for this study. Sex-specific measurements were also determined. Vertebral anatomy was studied to determine whether aberrant anatomy would preclude pedicle fixation. Statistical analyses were performed. Results Of the 47 patients, 27 were male. Overall mean C-2 pedicle widths and lengths were 8.272 ± 1.364 mm and 27.052 ± 3.471 mm, respectively. The average widths and lengths of the pedicle in female patients were 8.040 ± 1.262 mm and 27.241 ± 2.731 mm, respectively, and those in male patients were 8.444 ± 1.414 mm and 26.913 ± 3.933 mm, respectively. The sex difference was statistically significant for width (p = 0.012) but not for length (p = 0.41). On the basis of width, the percentages of pedicles that could tolerate a 3.5-mm and 4.0-mm screw were 98% and 97%, respectively. Vertebral anatomy precluded screw length greater than 14 mm for only 3 patients. Conclusions Using multidimensional CT or 3D imaging, the authors found that C-2 pedicles in over 90% of patients could tolerate 3.5-mm and 4.0-mm pedicle screws. Vertebral anatomy precluded use of screw lengths greater than 14 mm for only 3 (6%) of 47 patients. Therefore, the C-2 pedicle might be more tolerant of fixation than previously reported.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3