Longitudinal assessment of segmental motion of the cervical spine following total disc arthroplasty: a comparative analysis of devices

Author:

Colman Matthew W.1,Zavras Athan G.1,Federico Vincent P.1,Nolte Michael T.1,Butler Alexander J.1,Singh Kern1,Phillips Frank M.1

Affiliation:

1. Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois

Abstract

OBJECTIVE Total disc arthroplasty (TDA) has been shown to be an effective and safe treatment for cervical degenerative disc disease at short- and midterm follow-up. However, there remains a paucity of literature reporting the differences between individual prosthesis designs with regard to device performance. In this study, the authors evaluated the long-term maintenance of segmental range of motion (ROM) at the operative cervical level across a diverse range of TDA devices. METHODS In this study, the authors retrospectively evaluated all consecutive patients who underwent 1- or 2-level cervical TDA between 2005 and 2020 at a single institution. Patients with a minimum of 6 months of follow-up and lateral flexion/extension radiographs preoperatively, 2 months postoperatively, and at final follow-up were included. Radiographic measurements included static segmental lordosis, segmental range of motion (ROM) on flexion/extension, global cervical (C2–7) ROM on flexion/extension, and disc space height. The paired t-test was used to evaluate improvement in radiographic parameters. Subanalysis between devices was performed using one-way ANCOVA. Significance was determined at p < 0.05. RESULTS A total of 85 patients (100 discs) were included, with a mean patient age of 46.01 ± 8.82 years and follow-up of 43.56 ± 39.36 months. Implantations included 22 (22.00%) M6-C, 51 (51.00%) Mobi-C, 14 (14.00%) PCM, and 13 (13.00%) ProDisc-C devices. There were no differences in baseline radiographic parameters between groups. At 2 months postoperatively, PCM provided significantly less segmental lordosis (p = 0.037) and segmental ROM (p = 0.039). At final follow-up, segmental ROM with both the PCM and ProDisc-C devices was significantly less than that with the M6-C and Mobi-C devices (p = 0.015). From preoperatively to 2 months postoperatively, PCM implantation led to a significant loss of lordosis (p < 0.001) and segmental ROM (p = 0.005) relative to the other devices. Moreover, a significantly greater decline in segmental ROM from 2 months postoperatively to final follow-up was seen with ProDisc-C, while segmental ROM increased significantly over time with Mobi-C (p = 0.049). CONCLUSIONS Analysis by TDA device brand demonstrated that motion preservation differs depending on disc design. Certain devices, including M6-C and Mobi-C, improve ROM on flexion/extension from preoperatively to postoperatively and continue to increase slightly at final follow-up. On the other hand, devices such as PCM and ProDisc-C contributed to greater segmental stiffness, with a gradual decline in ROM seen with ProDisc-C. Further studies are needed to understand how much segmental ROM is ideal after TDA for preservation of physiological cervical kinematics.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3