Preclinical evaluation of a novel device for delivering brachytherapy to the margins of resected brain tumor cavities

Author:

Stubbs James B.,Frankel Roger H.,Schultz Karl,Crocker Ian,Dillehay Dirck,Olson Jeffrey J.

Abstract

Object. The objectives of this study were to evaluate the safety and performance of a new brachytherapy applicator in the treatment of resected brain tumors in a canine model. Methods. The brachytherapy applicator is an inflatable balloon catheter that is implanted in the resection cavity remaining after a brain tumor has been debulked. After implantation the balloon is inflated with Iotrex, a sterile solution containing organically bound iodine-125. The low-energy photons emitted by the iodine-125 deposit a therapeutic radiation dose across short distances from the surface of the balloon. After delivery of a prescribed radiation dose to the targeted volume, the radioactive fluid is retrieved and the catheter removed. Small resections of the right frontal lobe were performed in large dogs. Magnetic resonance (MR) images were obtained and used to assess tissue response and to measure the conformance between the resection cavity wall and the balloon surface. In four animals a dose ranging from 36 to 59 Gy was delivered. Neurological status and histological characteristics of the brain were assessed in all dogs. Implantation and explantation as well as inflation and deflation of the device were easily accomplished and well tolerated. The device was easily visualized on MR images, which demonstrated the expected postsurgical changes. The resection cavity and the balloon were highly conformal (range 93–100%). Histological changes to the cavity margin were consistent with those associated with surgical trauma. Additionally, radiation-related changes were observed at the margins of the resection cavity in dogs in which the brain was irradiated. Conclusions. This balloon catheter and 125I radiotherapy solution system can safely and reliably deliver radiation to the margins of brain cavities created by tumor resection. Results of this study showed that intracranial pressure changes due to balloon inflation and deflation were unremarkable and characteristic of the imaging properties and radiation safety profile of the device prior to its clinical evaluation. Clinically relevant brachytherapy (adequate target volume and total dose) was accomplished in all four animals subjected to treatment.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3