Gamma knife model C with the automatic positioning system and its impact on the treatment of vestibular schwannomas

Author:

Horstmann Gerhard A.,Van Eck Albertus T. C. J.

Abstract

Object. The aim of this study was to assess the effects of the gamma knife automatic positioning system (APS) on the treatment of patients, particularly effects of this system on the treatment of patients with vestibular schwannomas (VSs), with a view to reducing loss of hearing. Methods. The dose delivery with an increased number of shots was checked with GAFChromic Film for various numbers of shots (one to 129). The results in the first 549 patients were recorded. In addition a series of 59 patients with VSs treated with 13 Gy to the 65% isodose is presented. The authors have termed this the “13 on 65” concept. The film dosimetry showed that a large number of small shots did not materially affect the dose and dose distribution produced by gamma knife treatment. The APS was used alone in 72% of arteriovenous malformations, 71% of meningiomas, 94% of VSs, and 84% of pituitary adenomas. Metastatic tumors were accessible in a pure APS mode in 59% of all cases, glioma in 58%, and uveal melanoma in 10% of the cases. Thus two thirds of patients could be treated using APS alone. It was possible to use the APS and manual systems together for complex or very eccentrically placed targets. The APS resulted in the use of a larger number of isocenters. After a mean follow-up period of 15 months, the results in patients with the VSs in whom 13 Gy was delivered to the 65% isodose were similar to those in patients treated with the more conventional 50% margin isodose. There was no change in the incidence of hearing loss within the study period, and the incidence of trigeminal and facial neuropathies remained unchanged after treatment as well. Conclusions. The APS encourages the design of more conformal dose plans. The greater use of smaller collimators results in a steeper dose gradient with a smaller amount of radiation outside the target volume. Because the APS is able to apply a large number of smaller isocenters in an acceptable time, the number of isocenters used is increased. An increased number of isocenters can also be used to reduce the maximum radiation dose and increase the homogeneity in a given dose plan.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Cited by 40 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3