Efficacy and limitations of intraoperative spinal cord monitoring using nasopharyngeal tube electrodes

Author:

Yamamoto Naoya,Kobashi Hiroe,Shiba Masahiro,Itoh Tatsuo

Abstract

ObjectMotor evoked potentials are widely used for intraoperative spinal cord monitoring. However, there are problems with anesthetic constraints and high trial-by-trial variability of compound muscle action potential amplitude in muscle motor evoked potential monitoring. It is difficult to determine when to warn the surgeon of an occurrence of spinal cord risk. A method of estimation for motor function in the spinal cord has not been established. To monitor spinal cord function with reliable evoked potentials, including the upper cervical spinal cord and the ventral spinal cord, the authors developed a nasopharyngeal tube electrode that can be placed in front of the upper and ventral cervical spinal cord. The purpose of this study was to investigate the origins and pathways of descending or ascending spinal cord evoked potentials (SCEPs) elicited with this electrode, and the usefulness and limitations of this method.MethodsA nasopharyngeal tube electrode was inserted into the nostril. A catheter electrode was placed in the epidural or subarachnoid space at the thoracic spine. Ventral SCEP was recorded from the thoracic spinal cord after transpharyngeal stimulation, and dorsal SCEP was recorded with the nasopharyngeal electrode after thoracic spinal cord stimulation. There was no restriction of anesthetic technique in recording. When the amplitude of either of the SCEPs declined to 80% of the baseline, a warning was provided to the surgeon during the observed operative procedure. At the end of surgery, less than 50% or more than 30% of the baseline amplitude was considered a significant change in both SCEPs. The sensitivity and specificity for both SCEPs to detect neurological deterioration were calculated.ResultsThe electrode provided noninvasive access to the ventral cervicomedullary junction. The SCEPs showed stable responses. A response change was only observed in situations involving a risky procedure for the spinal cord. Ventral SCEPs showed high sensitivity (73.1%) for identifying patients with new neurological deficits or an exacerbation of preexisting neurological deficits after surgery, but dorsal SCEPs showed lower sensitivity (46.1%) in the total number of cases. Both SCEPs showed high specificities. The sensitivities of ventral SCEP, dorsal SCEP, and either SCEP were 100.0%, 50.0%, and 100.0% for the upper cervical spinal cord, 33.3%, 0%, and 55.6% for the lower cervical spinal cord, and 77.8%, 64.7%, and 88.2% for the thoracic spinal cord.ConclusionsCombined recording of both SCEPs estimated the ventral and dorsal white matter function in the spinal cord. Measuring the SCEPs with the nasopharyngeal electrode can be another useful approach for upper cervical and thoracic spinal cord monitoring. Ventral SCEP was more reliable for monitoring postoperative spinal cord function than dorsal SCEP. Ventral SCEP does not estimate the gray matter and spinal root functions in the lower cervical spinal cord.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3