Development of a relocatable frame technique for gamma knife radiosurgery

Author:

Walton Lee,Hampshire Anna,Roper Anthony,Mitchell Patrick,Vaughan Paul,Forster David M. C.,Kemeny Andras A.,Radatz Matthias W. R.

Abstract

Object. One of the limiting factors in gamma knife radiosurgery is the restriction to one treatment imposed by the fixed stereotactic frame. The ability, in selected cases, to remove the frame and replace it on a subsequent occasion in the same location would facilitate fractionated treatments and provide flexibility in the timing of treatment delivery. It is the purpose of this work to investigate techniques for frame fixation and for essential verification of frame position once it has been reapplied. Methods. A technique is proposed that requires four surgical self-tapping screws to be inserted into the skull. Aluminum pins are inserted through the frame pillars and are tightened against the head of the screws, providing a firm fixation of the frame. Pin lengths are recorded on gauges to ensure reproducibility of the position. In phantom tests, test objects were localized (using the angiographic localizer) before and after each of five frame removal/reapplications to test the reproducibility of frame position. The mean error in the observed target coordinates was 0.3 mm and the maximum error observed was 0.7 mm, indicating that the frame can be reapplied with some confidence. Repetition of bubble skull measurements has been investigated as a means of verifying that the frame was repositioned correctly; however, reproducibility of patient measurements was found to be poor even when no frame movement had occurred. In contrast, the use of a radiotherapy simulator to obtain repeated lateral and anteroposterior projections of the head was shown to be capable of detecting frame movements of as little as 1 mm. Conclusions. Using this technique of frame application facilitates the reapplication of the frame with an accuracy of plus or minus 0.7 mm. Bubble measurements are inadequate for the detection of frame movement. Simple techniques in which a radiotherapy simulator is used can verify correct frame placement and indicate frame movements of less than 1 mm.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Cited by 13 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3