Magnetic resonance imaging stereotactic target localization for deep brain stimulation in dystonic children

Author:

Vayssiere Nathalie,Hemm Simone,Zanca Michel,Picot Marie Christine,Bonafe Alain,Cif Laura,Frerebeau Philippe,Coubes Philippe

Abstract

Object. The actual distortion present in a given series of magnetic resonance (MR) images is difficult to establish. The purpose of this study was to validate an MR imaging—based methodology for stereotactic targeting of the internal globus pallidus during electrode implantation in children in whom general anesthesia had been induced.Methods. Twelve children (mean follow up 1 year) suffering from generalized dystonia were treated with deep brain stimulation by using a head frame and MR imaging. To analyze the influence of distortions at every step of the procedure, the geometrical characteristics of the frame were first controlled using the localizer as a phantom. Then pre- and postoperative coordinates of fixed anatomical landmarks and electrode positions, both determined with the head frame in place, were statistically compared.No significant difference was observed between theoretical and measured dimensions of the localizer (Student's t-test, |t| > 2.2 for 12 patients) in the x, y, and z directions.No significant differences were observed (Wilcoxon paired-sample test) between the following: 1) pre- and postoperative coordinates of the anterior commissure (AC) (Δx = 0.3 ± 0.29 mm and Δy = 0.34 ± 0.32 mm) and posterior commissure (PC) (Δx = 0.15 ± 0.18 mm and Δy = 0.34 ± 0.25 mm); 2) pre- and postoperative AC—PC distance (ΔL = 0.33 ± 0.22 mm); and 3) preoperative target and final electrode position coordinates (Δx = 0.24 ± 0.22 mm; Δy = 0.19 ± 0.16 mm).Conclusions. In the authors' center, MR imaging distortions did not induce detectable errors during stereotactic surgery in dystonic children. Target localization and electrode implantation could be achieved using MR imaging alone after induction of general anesthesia. The remarkable postoperative improvement in these patients confirmed the accuracy of the procedure (Burke—Marsden—Fahn Dystonia Rating Scale score Δ = −83.8%).

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Cited by 82 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3