Preoperative embolization of cerebral arteriovenous malformations with silk sutures: analysis and clinical correlation of complications revealed on computerized tomography scanning

Author:

Song Joon K.,Eskridge Joseph M.,Chung Eun-Chul,Blake Lindsey C.,Elliott J. Paul,Finch Lisa,Niakan Cyrus,Maravilla Kenneth R.,Winn H. Richard

Abstract

Object. The aim of this study was to determine the incidence and clinical significance of complications related to preoperative embolization of cerebral arteriovenous malformations (AVMs) with silk sutures as documented on postprocedure computerized tomography (CT) scans.Methods. The CT scans were obtained within 12 to 24 hours after 221 (96%) of 230 consecutive embolizations in 70 patients. These CT scans were evaluated for the presence of ischemia, infarction, hemorrhage, or contrast agent extravasation. Adverse patient outcomes were determined after each embolization and were correlated with CT findings. New abnormalities demonstrated on CT scans were also correlated with the Spetzler—Martin AVM grade, degree of arteriovenous shunting, and location. New abnormalities, the majority of them infarcts, resulted from 29 (13%) of 221 embolization procedures. In 11 (38%) of 29 cases of new CT findings, patients were asymptomatic, including 10 with new infarcts on CT scans. New neurological deficits occurred in 20 (8.7%) of 230 total embolization procedures in 19 patients, including one death. Permanent deficits occurred in nine patients (3.9% per embolization procedure, 12.8% per patient). Of the patients with new neurological deficits, 18 (90%) of 20 embolization procedures resulted in new abnormalities on CT scans. Two patients with new transient neurological deficits had no new findings on CT scans. Spetzler—Martin grade, AVM location, degree of arteriovenous shunting, and higher numbers of procedures were not statistically associated with a higher incidence of abnormalities on CT scans or new permanent neurological deficits.Conclusions. Silk sutures are an effective and relatively safe embolic agent. After brain AVM embolization with silk sutures, new abnormalities were found on CT scans obtained in one of eight procedures. When a new CT finding occurred, the patient had roughly equal chances of having no new symptoms, having new transient neurological deficits, or having new permanent neurological deficits.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Cited by 30 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3