In vivo intracranial pressure dynamics in patients with hydrocephalus treated by shunt placement

Author:

Frim David M.,Goumnerova Lilliana C.

Abstract

Object. With the commercial availability of a variety of shunt systems, there is considerable controversy over the choice of the most appropriate shunt valve for each individual with hydrocephalus. Although the performance characteristics of all shunt systems are well documented in the laboratory setting, there is little description of the in vivo dynamics of intracranial pressure (ICP) after implantation of commonly used shunt systems in humans. The authors coupled telemonitoring devices to several different shunt systems to measure the performance characteristics of these valve systems with respect to intraventricular pressure (IVP) at increments of head elevation.Methods. Twenty-five patients with different shunt systems and three control patients without shunts were studied for IVP at 0°, 15°, 30°, 45°, 60°, 75°, and 90° of head elevation, and the resultant curves were analyzed for the best-fit regression coefficient. For purposes of analysis the authors grouped shunt valve systems by design characteristics into three groups: differential-pressure valves (r = −0.321 ± 0.061; 11 patients), nonsiphoning systems (r = −0.158 ± 0.027; 10 patients), and flow-regulated valves (r = −0.16 ± 0.056; four patients); there were three control patients without shunts (r = −0.112 ± 0.037).Conclusions. The authors found that differential-pressure valves always caused ICP to drop to 0 by 30° of head elevation, whereas all other valve systems caused a more gradual drop in ICP, more consistent with pressures observed in the control patients without shunts. Not surprisingly, the differential-pressure valve group was found to have a significant difference in mean regression coefficient when compared with those in whom nonsiphoning shunts (p < 0.023) or no shunts were placed (p < 0.049). These data provide a basis for evaluating shunt valve performance and for predicting valve appropriateness in patients in whom characteristics such as pressure and flow dynamics are weighed in the choice of a specific valve for implantation.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3