Safety and efficacy of bihemispheric sampling via transmidline stereoelectroencephalography

Author:

Restrepo Carlos E.123,Balaguera Pedro243,Thompson Stephen A.243,Johnson Jessica12,Lacuey Nuria243,Pati Sandipan243,Harris Katherine243,Lhatoo Samden D.243,Tandon Nitin123

Affiliation:

1. Vivian L. Smith Department of Neurosurgery, McGovern Medical School at University of Texas Health Science Center at Houston;

2. Texas Institute for Restorative Neurotechnologies, University of Texas Health Science Center at Houston;

3. Memorial Hermann Hospital, Texas Medical Center, Houston, Texas

4. Department of Neurology, McGovern Medical School at University of Texas Health Science Center at Houston; and

Abstract

OBJECTIVE Stereoelectroencephalography (SEEG) is designed to target distributed cortical networks responsible for electroclinical seizure syndrome and to enable localization of the site of seizure onset in patients with intractable epilepsy. When the preimplantation hypothesis invokes the bilateral mesial frontal lobes, sampling of several deep-seated cortical sites in both hemispheres is required. In this study, the authors have demonstrated the feasibility of sampling bihemispheric areas with intentional implantation of an SEEG electrode crossing the midline (SECM) for sampling the cortex on both sides of the interhemispheric fissure. METHODS An analysis of 231 consecutive SEEG procedures over 8 years was used to identify instances of bihemispheric sampling by using the transmidline SEEG technique. RESULTS The authors identified 53 SEEG cases, with a total of 126 electrodes that crossed the interhemispheric fissure; all were in the frontal lobes. Eighty-three electrodes targeted the cingulate gyrus (18 rostral, 43 anterior, and 22 middle), 31 targeted the posterior orbitofrontal region, 8 sampled the medial prefrontal cortex, and 4 targeted nodular heterotopia around the frontal horns. The ictal onset zone was localized to the frontal lobe in 16 cases. SECM isolated interictal and ictal activity in the contralateral hemisphere in 6 cases and independent bihemispheric seizure activity in 2 cases. No hemorrhagic or infectious complications were noted in any of these cases. CONCLUSIONS Based on this extensive experience of bihemispheric sampling, the authors concluded that this technique is safe and effective. In this series, SECM showed contralateral interictal and/or ictal epileptiform activity in 8 (15%) cases, and 9 (16%) cases (with unilateral implantation) had sufficient data to discard contralateral involvement, contributing to support of the epileptogenic network. SECM may reduce the number of electrodes used to sample bilateral mesial frontal or orbitofrontal cortices, and such an approach may lower the risk of hemorrhage and costs.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3