Safety of magnetic resonance imaging of deep brain stimulator systems: a serial imaging and clinical retrospective study

Author:

Chhabra Vaninder1,Sung Edward2,Mewes Klaus3,Bakay Roy A. E.4,Abosch Aviva5,Gross Robert E.13

Affiliation:

1. Departments of Neurosurgery and

2. Emory University School of Medicine, Atlanta, Georgia;

3. Neurology,

4. Department of Neurosurgery, Rush University Medical Center, Chicago, Illinois; and

5. Department of Neurosurgery, University of Minnesota Medical School, Minneapolis, Minnesota

Abstract

Object With the expanding indications and increasing number of patients undergoing deep brain stimulation (DBS), postoperative MR imaging is becoming even more important in guiding clinical care and practice-based learning; important safety concerns have recently emerged, however. Although phantom model studies have driven conservative recommendations regarding imaging parameters, highlighted by 2 recent reports describing adverse neurological events associated with MR imaging in patients with implanted DBS systems, the risks of MR imaging in such patients in clinical practice has not been well addressed. In this study, the authors capitalized on their large experience with serial MR imaging (3 times per patient) to use MR imaging itself and clinical outcomes to examine the safety of MR imaging in patients who underwent staged implantation of DBS electrodes for Parkinson disease, tremor, and dystonia. Methods Sixty-four patients underwent staged bilateral lead implantations between 1997 and 2006, and each patient underwent 3 separate MR imaging sessions subsequent to DBS placement. The first of these was performed after the first DBS placement, the second occurred prior to the second DBS placement, and third was after the second DBS placement. Follow-up was conducted to examine adverse events related either to MR imaging or to DBS-induced injury. Results One hundred and ninety-two MR images were obtained, and the mean follow-up time was 3.67 years. The average time between the first and second, and second and third MR imaging sessions was 19.4 months and 14.7 hours, respectively. Twenty-two MR imaging–detected new findings of hemorrhage were documented. However, all new findings were related to acute DBS insertion, whereas there were no new findings after imaging of the chronically implanted electrode. Conclusions Although potential risks of MR imaging in patients undergoing DBS may be linked to excessive heating, induced electrical currents, disruption of the normal operation of the device, and/or magnetic field interactions, MR imaging can be performed safely in these patients and provides useful information on DBS lead location to inform patient-specific programming and practice-based learning.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

Cited by 38 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司