Pediatric stereo-electroencephalography: effects of robot assistance and other variables on seizure outcome and complications

Author:

Mavridis Ioannis N.1,Lo William B.1,Wimalachandra Welege Samantha Buddhika1,Philip Sunny2,Agrawal Shakti2,Scott Caroline3,Martin-Lamb Darren3,Carr Bryony3,Bill Peter3,Lawley Andrew3,Seri Stefano3,Walsh A. Richard1

Affiliation:

1. Departments of Neurosurgery,

2. Neurology, and

3. Neurophysiology, Birmingham Children’s Hospital, Birmingham, United Kingdom

Abstract

OBJECTIVE The safety of stereo-electroencephalography (SEEG) has been investigated; however, most studies have not differentiated pediatric and adult populations, which have different anatomy and physiology. The purpose of this study was to assess SEEG safety in the pediatric setting, focusing on surgical complications and the identification of patient and surgical risk factors, if any. The authors also aimed to determine whether robot assistance in SEEG was associated with a change in practice, surgical parameters, and clinical outcomes. METHODS The authors retrospectively studied all SEEG cases performed in their department from December 2014 to March 2020. They analyzed both demographic and surgical variables and noted the types of surgery-related complications and their management. They also studied the clinical outcomes of a subset of the patients in relation to robot-assisted and non–robot-assisted SEEG. RESULTS Sixty-three children had undergone 64 SEEG procedures. Girls were on average 3 years younger than the boys (mean age 11.1 vs 14.1 years, p < 0.01). The overall complication rate was 6.3%, and the complication rate for patients with left-sided electrodes was higher than that for patients with right-sided electrodes (11.1% vs 3.3%), although the difference between the two groups was not statistically significant. The duration of recording was positively correlated to the number of implanted electrodes (r = 0.296, p < 0.05). Robot assistance was associated with a higher number of implanted electrodes (mean 12.6 vs 7.6 electrodes, p < 0.0001). Robot-assisted implantations were more accurate, with a mean error of 1.51 mm at the target compared to 2.98 mm in nonrobot implantations (p < 0.001). Clinical outcomes were assessed in the first 32 patients treated (16 in the nonrobot group and 16 in the robot group), 23 of whom proceeded to further resective surgery. The children who had undergone robot-assisted SEEG had better eventual seizure control following subsequent epilepsy surgery. Of the children who had undergone resective epilepsy surgery, 42% (5/12) in the nonrobot group and 82% (9/11) in the robot group obtained an Engel class IA outcome at 1 year (χ2 = 3.885, p = 0.049). Based on Kaplan-Meier survival analysis, the robot group had a higher seizure-free rate than the nonrobot group at 30 months postoperation (7/11 vs 2/12, p = 0.063). Two complications, whose causes were attributed to the implantation and head-bandaging steps, required surgical intervention. All complications were either transient or reversible. CONCLUSIONS This is the largest single-center, exclusively pediatric SEEG series that includes robot assistance so far. SEEG complications are uncommon and usually transient or treatable. Robot assistance enabled implantation of more electrodes and improved epilepsy surgery outcomes, as compared to those in the non–robot-assisted cases.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3