Utility of tubular retractors to minimize surgical brain injury in the removal of deep intraparenchymal lesions: a quantitative analysis of FLAIR hyperintensity and apparent diffusion coefficient maps

Author:

Bander Evan D.1,Jones Samuel H.1,Kovanlikaya Ilhami2,Schwartz Theodore H.345

Affiliation:

1. Weill Cornell Medical College, NewYork-Presbyterian Hospital, New York, New York

2. Radiology,

3. Departments of Neurosurgery,

4. Otolaryngology,

5. Neuroscience, and

Abstract

OBJECT Brain retraction systems are frequently required to achieve surgical exposure of deep-seated brain lesions. Spatula-based systems can be associated with injury to the cortex and deep white matter, particularly adjacent to the sharp edges, which can result in uneven pressure on the parenchyma over the course of a long operation. The use of tubular retractor systems has been proposed as a method to overcome these limitations. There have been no studies assessing the degree of brain injury associated with the use of tubular retractors. METHODS Twenty patients were retrospectively identified at Weill Cornell Medical College who underwent resection of deep-seated brain lesions between 2005 and 2014 with the aid of a METRx tubular retractor system. Using the Brainlab software, pre- and postoperative images were analyzed to assess volume, depth, extent of resection, and change in postoperative MR FLAIR hyperintensity and restricted diffusion on diffusion-weighted imaging (DWI). RESULTS The mean preoperative tumor volume was 16.25 ± 17.6 cm3. Gross-total resection was achieved in 75%, near-total resection in 10%, and subtotal resection in 15% of patients. There was a small but not statistically significant increase in average FLAIR hyperintensity volume by 3.25 ± 10.51 cm3 (p = 0.16). The average postoperative volume of DWI high signal area with restricted diffusion on apparent diffusion coefficient maps was 8.35 ± 3.05 cm3. Assuming that the volume of restricted diffusion on DWI around tumor was 0 preoperatively, this represented a statistically significant increase on DWI (p < 0.001). CONCLUSIONS Although tubular retractors do not appear to significantly increase FLAIR signal in the brain, DWI intensity around the retractors can be identified. These data indicate that although tubular retractors may minimize damage to surrounding tissues, they still cause cytotoxic edema and cellular damage. Objective comparison against other retraction methods, as compared by 3D volumetric analysis or similar methods, will be important in determining the true advantage of tubular retractor systems.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3