Differential pressure in shunt therapy: investigation of position-dependent intraperitoneal pressure in a porcine model

Author:

Freimann Florian Baptist1,Ötvös Jens2,Chopra Sascha Santosh3,Vajkoczy Peter1,Wolf Stefan1,Sprung Christian1

Affiliation:

1. Departments of Neurosurgery,

2. Experimental Medicine, and

3. General, Visceral and Transplantation Surgery, Charité–Universitätsmedizin Berlin, Germany

Abstract

Object The differential pressure between the intracranial and intraperitoneal cavities is essential for ventriculoperitoneal shunting. A determination of the pressure in both cavities is decisive for selecting the appropriate valve type and opening pressure. The intraperitoneal pressure (IPP)—in contrast to the intracranial pressure—still remains controversial with regard to its normal level and position dependency. Methods The authors used 6 female pigs for the experiments. Two transdermal telemetric pressure sensors (cranial and caudal) were implanted intraperitoneally with a craniocaudal distance of 30 cm. Direct IPP measurements were supplemented with noninvasive IPP measurements (intragastral and intravesical). The IPP was measured with the pigs in the supine (0°), 30°, 60°, and vertical (90°) body positions. After the pigs were euthanized, CT was used to determine the intraperitoneal probe position. Results With pigs in the supine position, the mean (± SD) IPP was 10.0 ± 3.5 cm H2O in a mean vertical distance of 4.5 ± 2.8 cm to the highest level of the peritoneum. The difference between the mean IPP of the cranially and the caudally implanted probes (Δ IPP) increased according to position, from 5.5 cm H2O in the 0° position to 11.5 cm H2O in the 30° position, 18.3 cm H2O in the 60° position, and 25.6 cm H2O in the vertical body position. The vertical distance between the probe tips (cranially implanted over caudally implanted) increased 3.4, 11.2, 19.3, and 22.3 cm for each of the 4 body positions, respectively. The mean difference between the Δ IPP and the vertical distance between both probe tips over all body positions was 1.7 cm H2O. Conclusions The IPP is subject to the position-dependent hydrostatic force. Normal IPP is able to reduce the differential pressure in patients with ventriculoperitoneal shunts.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3