Biomechanical comparison between C-7 lateral mass and pedicle screws in subaxial cervical constructs

Author:

Xu Risheng123,McGirt Matthew J.23,Sutter Edward G.3,Sciubba Daniel M.23,Wolinsky Jean-Paul23,Witham Timothy F.23,Gokaslan Ziya L.23,Bydon Ali23

Affiliation:

1. 1Medical Scientist Training Program, Johns Hopkins School of Medicine;

2. 2Department of Neurosurgery, Johns Hopkins Hospital; and

3. 3Johns Hopkins Spinal Column Biomechanics and Surgical Outcomes Laboratory, Johns Hopkins Bayview Medical Center, Baltimore, Maryland

Abstract

Object The aim of this study was to conduct the first in vitro biomechanical comparison of immediate and postcyclical rigidities of C-7 lateral mass versus C-7 pedicle screws in posterior C4–7 constructs. Methods Ten human cadaveric spines were treated with C4–6 lateral mass screw and C-7 lateral mass (5 specimens) versus pedicle (5 specimens) screw fixation. Spines were potted in polymethylmethacrylate bone cement and placed on a materials testing machine. Rotation about the axis of bending was measured using passive retroreflective markers and infrared motion capture cameras. The motion of C-4 relative to C-7 in flexion-extension and lateral bending was assessed uninstrumented, immediately after instrumentation, and following 40,000 cycles of 4 Nm of flexion-extension and lateral bending moments at 1 Hz. The effect of instrumentation and cyclical loading on rotational motion across C4–7 was analyzed for significance. Results Preinstrumented spines for the 2 cohorts were comparable in bone mineral density and range of motion in both flexion-extension (p = 0.33) and lateral bending (p = 0.16). Lateral mass and pedicle screw constructs significantly reduced motion during flexion-extension (11.3°–0.26° for lateral mass screws, p = 0.002; 10.51°–0.30° for pedicle screws, p = 0.008) and lateral bending (7.38°–0.27° for lateral mass screws, p = 0.003; 11.65°–0.49° for pedicle screws, p = 0.03). After cyclical loading in both cohorts, rotational motion over C4–7 was increased during flexion-extension (0.26°–0.68° for lateral mass screws; 0.30°–1.31° for pedicle screws) and lateral bending (0.27°–0.39° and 0.49°–0.80°, respectively), although the increase was not statistically significant (p > 0.05). There was no statistical difference in postcyclical flexion-extension (p = 0.20) and lateral bending (0.10) between lateral mass and pedicle screws. Conclusions Both C-7 lateral mass and C-7 pedicle screws allow equally rigid fixation of subaxial lateral mass constructs ending at C-7. Immediately and within a simulated 6-week postfixation period, C-7 lateral mass screws may be as effective as C-7 pedicle screws in biomechanically stabilizing long subaxial lateral mass constructs.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3