Immediate and midterm follow-up results of using an electrodetachable, fully retrievable SOLO stent system in the endovascular coil occlusion of wide-necked cerebral aneurysms

Author:

Yavuz Kivilcim1,Geyik Serdar1,Pamuk Almila Gulsun2,Koc Osman1,Saatci Isil1,Cekirge H. Saruhan1

Affiliation:

1. Departments of Radiology; and

2. Anesthesiology, Hacettepe University Hospitals, Ankara, Turkey

Abstract

Object Stent-assisted embolization is an alternative endovascular treatment method for wide-necked intracranial aneurysms. Currently available stents have the limitations of poor radial force, difficult delivery systems, and lack of full retrievability. The authors report on their preliminary experience with the use of a new, fully retrievable, self-expanding neurovascular stent, which has a high radial force and easy delivery system, combined with coil or Onyx embolization for the treatment of wide-necked aneurysms, including 6-month follow-up data. Methods Fifteen patients with 18 wide-necked intracranial aneurysms were treated using the SOLO stent system and detachable platinum coils. Aneurysms were located at the posterior communicating artery (seven lesions), midbasilar artery (one lesion), internal carotid artery (ICA) bifurcation (one lesion), ICA–ophthalmic artery segment (eight lesions), and posterior cerebral artery (one lesion). Eleven aneurysms were small, six were large, and one was giant. Only one of these aneurysms was in the acute stage of subarachnoid hemorrhage; balloon remodeling alone failed to keep the coils in the aneurysm sac. Results Only one stent required retrieving and repositioning after it had been fully deployed, and retrieval was easy and successful. No thromboembolic complication, dissection/rupture, or vasospasm occured during stent placement. Follow-up angiograms obtained at 6 months posttreatment in the 18 aneurysms demonstrated that all stents were patent with no evidence of intimal hyperplasia or stenosis. In all cases but one, 100% lesion occlusion was observed at the 6-month control angiography examination. Only one aneurysm had recanalized. Conclusions The fully retrievable self-expandible SOLO stent is a feasible, secure, and effective system with a high radial force and ease of delivery in treating wide-necked intracranial aneurysms in combination with coil embolization.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Cited by 64 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3