Crescent sign on magnetic resonance angiography revealing incomplete stent apposition: correlation with diffusion-weighted changes in stent-mediated coil embolization of aneurysms

Author:

Heller Robert S.12,Miele William R.12,Do-Dai Daniel D.32,Malek Adel M.132

Affiliation:

1. Cerebrovascular and Endovascular Division, Department of Neurosurgery,

2. Tufts University School of Medicine, Boston, Massachusetts

3. Department of Radiology, Tufts Medical Center; and

Abstract

Object Few data are available on how closely stents appose the luminal vessel wall in stent-mediated coil embolization of intracranial aneurysms and on the effect of incomplete stent apposition on procedural thromboembolic complications. Methods Postprocedural 3-T MR diffusion-weighted imaging and time-of-flight angiography were obtained in 58 patients undergoing stent-mediated coil embolization of aneurysms using the Enterprise closed-cell and Neuroform open-cell self-expanding intracranial microstents. Results A distinctive semilunar signal pattern, identified using 3-T MR angiography, represented flow outside the confines of the stent struts in patients in whom Enterprise but not Neuroform devices were used. This pattern, designated as the crescent sign, was confirmed to correspond to incomplete stent apposition by use of high-resolution angiographic flat-panel CT scanning revealing flow ingress into and egress out of the isolated luminal wedge. The presence of the crescent sign was seen in 18 of 33 Enterprise-treated but in 0 of 25 Neuroform-treated cases, and was more likely in stents delivered in the tortuous internal carotid artery (p = 0.034). The crescent sign was strongly predictive of ipsilateral postprocedural lesions seen on diffusion-weighted imaging in the entire population (OR 18, 95% CI 4.33–74.8; p < 0.0001). In the Enterprise stent subset, ipsilateral lesions were detected on diffusion-weighted imaging in 15 (45%) of 33 cases; the crescent sign was seen in 12 (80%) of 15 patients with ipsilateral lesions on diffusion-weighted imaging, but in only 6 of 18 patients without lesions (OR 8, 95% CI 1.61–39.6; p = 0.006). Conclusions Incomplete stent apposition is detectable on 3-T MR angiography as a crescent sign, and was found to be highly prevalent in Enterprise closed-cell design stents used to assist coil embolization of aneurysms. Incomplete stent apposition was also associated with periprocedural ipsilateral hyperintense lesions on diffusion-weighted imaging. These results identify an association between incomplete stent apposition and thromboembolic complications in stent-mediated coil embolization of intracranial aneurysms.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

Cited by 56 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3