Abstract

Object Accurate insertion of C-2 cervical screws is imperative; however, the procedures for C-2 screw insertion are technically demanding and challenging, especially in cases of C-2 vertebral abnormality. The purpose of this study is to report the effectiveness of the tailor-made screw guide template (SGT) system for placement of C-2 screws, including in cases with abnormalities. Methods Twenty-three patients who underwent posterior spinal fusion surgery with C-2 cervical screw insertion using the SGT system were included. The preoperative bone image on CT was analyzed using multiplanar imaging software. The trajectory and depth of the screws were designed based on these images, and transparent templates with screw guiding cylinders were created for each lamina. During the operation, after templates were engaged directly to the laminae, drilling, tapping, and screwing were performed through the templates. The authors placed 26 pedicle screws, 12 pars screws, 6 laminar screws, and 4 C1–2 transarticular screws using the SGT system. To assess the accuracy of the screw track under this system, the deviation of the screw axis from the preplanned trajectory was evaluated on postoperative CT and was classified as follows: Class 1 (accurate), a screw axis deviation less than 2 mm from the planned trajectory; Class 2 (inaccurate), 2 mm or more but less than 4 mm; and Class 3 (deviated), 4 mm or more. In addition, to assess the safety of the screw insertion, malpositioning of the screws was also evaluated using the following grading system: Grade 0 (containing), a screw is completely within the wall of the bone structure; Grade 1 (exposure), a screw perforates the wall of the bone structure but more than 50% of the screw diameter remains within the bone; Grade 2 (perforation), a screw perforates the bone structures and more than 50% of the screw diameter is outside the pedicle; and Grade 3 (penetration), a screw perforates completely outside the bone structure. Results In total, 47 (97.9%) of 48 screws were classified into Class 1 and Grade 0, whereas 1 laminar screw was classified as Class 3 and Grade 2. Mean screw deviations were 0.36 mm in the axial plane (range 0.0–3.8 mm) and 0.30 mm in the sagittal plane (range 0.0–0.8 mm). Conclusions This study demonstrates that the SGT system provided extremely accurate C-2 cervical screw insertion without configuration of reference points, high-dose radiation from intraoperative 3D navigation, or any registration or probing error evoked by changes in spinal alignment during surgery. A multistep screw placement technique and reliable screw guide cylinders were the key to accurate screw placement using the SGT system.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3