Complex pediatric cervical spine surgery using smaller nonspinal screws and plates and intraoperative computed tomography

Author:

Karandikar Mahesh1,Mirza Sohail K.2,Song Kit3,Yang Tong1,Krengel Walter F.13,Spratt Kevin F.2,Avellino Anthony M.13

Affiliation:

1. Departments of Neurological Surgery and

2. Department of Orthopedics, Dartmouth Medical School, Hanover, New Hampshire

3. Orthopaedic Surgery, Harborview Medical Center, University of Washington School of Medicine, Seattle Children's Hospital, Seattle, Washington; and

Abstract

Object The treatment of craniocervical instability in children is often challenging due to their small spine bones, complex anatomy, and unique syndromes. The authors discuss their surgical experience with 33 cases in the treatment of 31 children (≤17 years of age) with craniocervical spine instability using smaller nontraditional titanium screws and plates, as well as intraoperative CT. Methods All craniocervical fusion procedures were performed using intraoperative fluoroscopic imaging and electrophysiological monitoring. Nontraditional spine hardware included smaller screw sizes (2.4 and 2.7 mm) from the orthopedic hand/foot set and mandibular plates. Twenty-three of the 33 surgical procedures were performed with intraoperative CT, which was used to confirm adequate position of the spine hardware and alignment of the spine. Results The mean patient age was 9.5 years (range 2–17 years). Eleven children underwent a posterior C1–2 transarticular screw fusion, 17 had an occipitocervical fusion, and 3 had a posterior subaxial cervical fusion. The follow-up duration ranged from 9 to 72 months (mean 53 months). All children demonstrated successful fusion at their 3-month follow-up visit, except 1 patient whose unilateral C1–2 transarticular screw fusion required a repeat surgery before proper fusion was achieved. Of the 47 C1–2 transarticular screws that were placed, 13 were 2.4 mm, 15 were 2.7 mm, 7 were 3.5 mm, and 12 were 4.0 mm. Eighteen of the 47 C1–2 transarticular screws were suboptimally placed. Eleven of these misplaced screws were removed and redirected within the same operation because these surgeries benefitted from the use of intraoperative CT; 6 of the 7 remaining suboptimally placed screws were left in place because a second surgery for screw replacement was not warranted. The other suboptimally placed C1–2 screw was replaced during a repeat operation due to failure of fusion. Use of intraoperative CT was invaluable because it enabled the authors to reposition suboptimal C1–2 transarticular screws without necessitating a second operation. Conclusions Successful craniocervical fusion procedures were achieved using smaller nontraditional titanium screws and plates. Intraoperative CT was a helpful adjunct for confirming and readjusting the trajectory of the screws prior to leaving the operating room, which decreases overall treatment costs and reduces complications.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

Cited by 13 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3