A multicenter, open-label, controlled trial on acceptance, convenience, and complications of rechargeable internal pulse generators for deep brain stimulation: the Multi Recharge Trial

Author:

Jakobs Martin12,Helmers Ann-Kristin3,Synowitz Michael3,Slotty Philipp J.4,Anthofer Judith M.5,Schlaier Jürgen R.5,Kloss Manja6,Unterberg Andreas W.2,Kiening Karl L.12

Affiliation:

1. Department of Neurosurgery, Division of Stereotactic Neurosurgery, and

2. Departments of Neurosurgery and

3. Department of Neurosurgery, University Medical Center Schleswig-Holstein, Campus Kiel, Christian-Albrechts-University Kiel, Kiel;

4. Department of Stereotactic and Functional Neurosurgery, University Hospital Düsseldorf, Heinrich-Heine University Düsseldorf, Düsseldorf; and

5. Department of Neurosurgery, University Hospital Regensburg, Regensburg, Germany

6. Neurology, University Hospital Heidelberg, Heidelberg;

Abstract

OBJECTIVERechargeable neurostimulators for deep brain stimulation have been available since 2008, promising longer battery life and fewer replacement surgeries compared to non-rechargeable systems. Long-term data on how recharging affects movement disorder patients are sparse. This is the first multicenter, patient-focused, industry-independent study on rechargeable neurostimulators.METHODSFour neurosurgical centers sent a questionnaire to all adult movement disorder patients with a rechargeable neurostimulator implanted at the time of the trial. The primary endpoint was the convenience of the recharging process rated on an ordinal scale from “very hard” (1) to “very easy” (5). Secondary endpoints were charge burden (time spent per week on recharging), user confidence, and complication rates. Endpoints were compared for several subgroups.RESULTSDatasets of 195 movement disorder patients (66.1% of sent questionnaires) with Parkinson’s disease (PD), tremor, or dystonia were returned and included in the analysis. Patients had a mean age of 61.3 years and the device was implanted for a mean of 40.3 months. The overall convenience of recharging was rated as “easy” (4). The mean charge burden was 122 min/wk and showed a positive correlation with duration of therapy; 93.8% of users felt confident recharging the device. The rate of surgical revisions was 4.1%, and the infection rate was 2.1%. Failed recharges occurred in 8.7% of patients, and 3.6% of patients experienced an interruption of therapy because of a failed recharge. Convenience ratings by PD patients were significantly worse than ratings by dystonia patients. Caregivers recharged the device for the patient in 12.3% of cases. Patients who switched from a non-rechargeable to a rechargeable neurostimulator found recharging to be significantly less convenient at a higher charge burden than did patients whose primary implant was rechargeable. Age did not have a significant impact on any endpoint.CONCLUSIONSOverall, patients with movement disorders rated recharging as easy, with low complication rates and acceptable charge burden.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3