A clinical analysis of 4- and 6-year follow-up results after cervical disc replacement surgery using the Bryan Cervical Disc Prosthesis

Author:

Goffin Jan1,van Loon Johan1,Van Calenbergh Frank1,Lipscomb Bailey2

Affiliation:

1. 1Department of Neurosurgery, Catholic University of Leuven, Belgium; and

2. 2Medtronic Spinal and Biologics, Memphis, Tennessee

Abstract

Object In this study, long-term results are presented from clinical studies of the Bryan Cervical Disc Prosthesis at University Hospital Gasthuisberg in Leuven, Belgium. A total of 98 patients (89 with 1-level and 9 with 2-level implantations) agreed to participate in follow-up studies for up to 10 years postoperatively. This article focuses on the 4- and 6-year results. Patients in one of the clinical studies had either radiculopathy or myelopathy associated with spondylosis and/or disc herniations that did not respond to conservative treatment. Patients from the other clinical study received commercially available Bryan devices and the study protocol did not have specific inclusion/exclusion criteria. More than 90% of the patients were considered to have radiculopathy. Methods Clinical measurements discussed in the article include the 36-Item Short Form Health Survey, Neck Disability Index, numerical ratings of neck and arm pain, neurological outcomes, and Odom classification. Angular motion findings from lateral flexion-extension radiographs are also presented. The occurrence of adverse events and second surgeries are examined as an indicator of device safety. Results The clinical outcomes at 4 and 6 years postoperatively appear consistent with the previously reported results at 1 and 2 years postoperatively. The mean angular motion results at 4 and 6 years postoperatively for 1-level patients were 7.3 and 7.7°, respectively. Two-level patients had slightly less motion at 4 and 6 years postoperatively with mean caudad values of 5.7 and 6.0°, respectively, and cephalad values of 4.2 and 6.2°, respectively. Efforts were made to capture adverse events, regardless of their nature and relatedness to the study surgery. This effort resulted in a relatively high number of recorded events. However, only 6 patients experienced events that were judged by the investigator to be related, either possibly or definitely, to the Bryan device. These events included device migration, device removal, and hoarseness and vocal cord paralysis, as well as 3 cases involving pain and neurological symptoms. Eight patients underwent further neck surgery to treat symptoms. Conclusions The favorable clinical and angular motion outcomes that were previously noted at 1- and 2-years' follow-up after cervical disc replacement with the Bryan Cervical Disc Prosthesis appear to persist after 4 and 6 years of follow-up.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

Cited by 82 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3