Complications following decompression of Chiari malformation Type I in children: dural graft or sealant?

Author:

Parker Stephen R.1,Harris Peggy1,Cummings Thomas J.1,George Timothy2,Fuchs Herbert1,Grant Gerald1

Affiliation:

1. Division of Neurosurgery, Department of Surgery, Duke University Medical Center, Durham, North Carolina; and

2. Pediatric Neurosurgery Center of Central Texas at Dell Children's Hospital, Austin, Texas

Abstract

Object Posterior fossa decompression with duraplasty for Chiari malformation Type I (CM-I) is a common pediatric neurosurgery procedure. Published series report a complication rate ranging from 3% to 40% for this procedure. Historically, many dural substitutes have been used, including bovine grafts, human cadaveric pericardium, synthetic dura, and autologous pericranium. The authors hypothesized that a recently observed increase in complications was dependent on the graft used. Methods Between January 2004 and January 2008, 114 consecutive patients ≤ 18 years old underwent primary CM-I decompression using duraplasty. Records were retrospectively reviewed for short- and intermediate-term complications and operative technique, focusing on the choice of duraplasty graft with or without application of a tissue sealant. Results The average age of the patients was 8.6 years. The dural graft used was variable: 15 were treated with cadaveric pericardium, 12 with Durepair, and 87 with EnDura. Tisseel was used in 75 patients, DuraSeal in 12, and no tissue sealant was used in 27 patients. The overall complication rate was 21.1%. The most common complications included aseptic meningitis, symptomatic pseudomeningocele, or a CSF leak requiring reoperation. The overall complication rates were as follows: cadaveric pericardium 26.7%, Durepair 41.7%, and EnDura 17.2%; reoperation rates were 13%, 25%, and 8.1%, respectively. Prior to adopting a different graft product, the overall complication rate was 18.1%; following the change the rate increased to 35%. Complication rates for tissue sealants were 14.8% for no sealant, 18.7% for Tisseel, and 50% for DuraSeal. Nine patients were treated with the combination of Durepair and DuraSeal and this subgroup had a 56% complication rate. Conclusions Complication rates after CM-I decompression may be dependent on the dural graft with or without the addition of tissue sealant. The complication rate at the authors' institution approximately doubled following the adoption of a different graft product. Tissue sealants used in combination with a dural substitute to augment a duraplasty may increase the risk of aseptic meningitis and/or CSF leak. The mechanism of the apparent increased inflammation with this combination remains under investigation.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3