Safety results from the treatment of 109 cerebral aneurysms using the Woven EndoBridge technique: preliminary results in the United Kingdom

Author:

Lawson Aimee1,Molyneux Andy2,Sellar Robin3,Lamin Saleh4,Thomas Allan4,Gholkar Anil5,Patankar Tufail1

Affiliation:

1. Leeds Teaching Hospitals NHS Trust, Great George Street, Leeds;

2. Nuffield Department of Surgical Sciences, University of Oxford;

3. Royal Infirmary of Edinburgh;

4. Queen Elizabeth Hospital, Birmingham; and

5. Royal Victoria Infirmary, Newcastle Upon Tyne, United Kingdom

Abstract

OBJECTIVEThe Woven Endobridge (WEB) device has been in clinical use for the treatment of brain aneurysms for the past 4 years. Observational studies to assess clinical outcome and related complications have been published. Clear evidence is required to better understand the safety profile of the WEB device. The authors here present a multicenter series that provides a detailed safety analysis focused on patient selection, procedural events, and technical issues of treated patients throughout the United Kingdom (UK).METHODSA nationwide password-protected database was set up to collect anonymous information across the UK (14 centers). Complications and clinical outcome were analyzed for the initial 109 patients (112 procedures). An independent root cause analysis classified the complications into groups (procedural, disease, device, ancillary device, and other). The modified Rankin Scale (mRS) was used as a marker of clinical outcome.RESULTSEach of the 109 patients had 1 aneurysm suitable for WEB treatment (109 aneurysms). Three patients had 2 procedures, making a total of 112 procedures performed. Eight procedures were abandoned because of access issues; 2 patients went on to have a successful procedure. All 109 patients had a preprocedure and discharge mRS scores recorded. One hundred patients had a recorded mRS score from a > 3-month follow-up.Deployment of the WEB device was successful in 103 (94.5%) of 109 patients and 104 (92.9%) of 112 procedures. One patient had 2 successful WEB procedures on separate occasions. Patients without a successfully implanted WEB device were included in the analysis. Selection analysis showed that the average patient age was 56.5 years among 34 men and 75 women. The percentage of incidental aneurysms was 58.7%, acute 16.5%, symptomatic 18.3%, and recurrent 6.4%. Further results analysis showed that 40 (36.7%) of 109 patients had recorded adverse events, including those unrelated to the WEB device. Events that could be related to the WEB device numbered 17 (15.6%) among the 109 patients. Two patients with device-related complications were symptomatic. Overall, 11 patients (10.1%) had persistent clinical sequelae. Thromboembolism was the most prevalent event, affecting 15.6% of the patients (17 of 109), and 6.4% of the patients (7 of 109) with a thromboembolism were symptomatic.Overall mortality before discharge was 0% and at the > 3-month follow-up was 5% (5 of 100 patients). Morbidity was defined as an mRS score increase to > 2. Overall morbidity at discharge was 1.8% (2 of 109) and at the > 3-month follow-up was 6% (6 of 100). No device-related morbidity or mortality was associated with this group.CONCLUSIONSThe UK data show that the WEB device is safe for clinical use. Thromboembolic complication adds a risk that should be minimized with appropriate anticoagulation and correct sizing of the device. There is scope for further evaluation and standardization of an anticoagulation regimen for the WEB device.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3