Dynamic telescopic craniotomy: a cadaveric study of a novel device and technique

Author:

Khanna Rohit12,Ferrara Lisa3

Affiliation:

1. Neurosurgery Service, Halifax Health;

2. Florida State University College of Medicine, Daytona Beach, Florida; and

3. OrthoKinetic Technologies LLC, Southport, North Carolina

Abstract

OBJECT The authors assessed the feasibility of the dynamic decompressive craniotomy technique using a novel cranial fixation plate with a telescopic component. Following a craniotomy in human cadaver skulls, the telescopic plates were placed to cover the bur holes. The plates allow constrained outward movement of the bone flap upon an increase in intracranial pressure (ICP) and also prevent the bone flap from sinking once the ICP normalizes. The authors compared the extent of postcraniotomy ICP control after an abrupt increase in intracranial volume using the dynamic craniotomy technique versus the standard craniotomy or hinge craniotomy techniques. METHODS Fixation of the bone flap after craniotomy was performed in 5 cadaver skulls using 3 techniques: 1) dynamic telescopic craniotomy, 2) hinge craniotomy, and 3) standard craniotomy with fixed plates. The ability of each technique to allow for expansion during intracranial hypertension was evaluated by progressively increasing intracranial volume. Biomechanical evaluation of the telescopic plates with load-bearing tests was also undertaken. RESULTS Both the dynamic craniotomy and the hinge craniotomy techniques provided significant control of ICP during increases in intracranial volume as compared with the standard craniotomy technique. With the standard craniotomy, ICP increased from a mean of 11.4 to 100.1 mm Hg with the addition of 120 ml of intracranial volume. However, with the dynamic craniotomy, the addition of 120 ml of intracranial volume increased the ICP from a mean of 2.8 to 13.4 mm Hg, maintaining ICP within the normal range as compared with the standard craniotomy (p = 0.04). The dynamic craniotomy was also superior in controlling ICP as compared with the hinge craniotomy, providing expansion for an additional 40 ml of intracranial volume while maintaining ICP within a normal range (p = 0.008). Biomechanical load-bearing tests for the dynamic telescopic plates revealed rigid restriction of bone-flap sinking as compared with standard fixation plates and clamps. CONCLUSIONS The dynamic telescopic craniotomy technique with the novel cranial fixation plate provides superior control of ICP after an abrupt increase in intracranial volume as compared with the standard craniotomy and hinge craniotomy techniques.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3