Assessment of intracranial dynamics in hydrocephalus: effects of viscoelasticity on the outcome of infusion tests

Author:

Bottan Simone1,Schmid Daners Marianne2,de Zelicourt Diane3,Fellner Norina1,Poulikakos Dimos1,Kurtcuoglu Vartan3

Affiliation:

1. Laboratory of Thermodynamics in Emerging Technologies;

2. Institute for Dynamic Systems and Control, ETH Zurich; and

3. The Interface Group, Institute of Physiology, University of Zurich, Switzerland

Abstract

Object The treatment of hydrocephalus requires insight into the intracranial dynamics in the patient. Resistance to CSF outflow (R0) is a clinically obtainable parameter of intracranial fluid dynamics that quantifies the apparent resistance to CSF absorption. It is used as a criterion for the selection of shunt candidates and serves as an indicator of shunt performance. The R0 is obtained clinically by performing 1 of 3 infusion tests: constant flow, constant pressure, or bolus infusion. Among these, the bolus infusion method has the shortest examination times and provides the shortest time of exposure of patients to artificially increased intracranial pressure (ICP) levels. However, for unknown reasons, the bolus infusion method systematically underestimates the R0. Here, the authors have tested and verified the hypothesis that this underestimation is due to lack of accounting for viscoelasticity of the craniospinal space in the calculation of the R0. Methods The authors developed a phantom model of the human craniospinal space in order to reproduce in vivo pressure-volume (PV) relationships during infusion testing. The phantom model followed the Marmarou exponential PV equation and also included a viscoelastic response to volume changes. Parameters of intracranial fluid dynamics, such as the R0, could be controlled and set independently. In addition to the phantom model, the authors designed a computational framework for virtual infusion testing in which viscoelasticity can be turned on or off in a controlled manner. Constant flow, constant pressure, and bolus infusion tests were performed on the phantom model, as well as on the virtual computational platform, using standard clinical protocols. Values for the R0 were derived from each infusion test by using both a standard method based on the Marmarou PV equation and a novel method based on a system identification approach that takes into account viscoelastic behavior. Results Experiments with the phantom model confirmed clinical observations that both the constant flow and constant pressure infusion tests, but not the bolus infusion test, yield correct R0 values when they are determined with the standard method according to Marmarou. Equivalent results were obtained using the computational framework. When the novel system identification approach was used to determine the R0, all of the 3 infusion tests yielded correct values for the R0. Conclusions The authors' investigations demonstrate that intracranial dynamics have a substantial viscoelastic component. When this viscoelastic component is taken into account in calculations, the R0, is no longer underestimated in the bolus infusion test.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3