Mechanical dysfunction of ventriculoperitoneal shunts caused by calcification of the silicone rubber catheter

Author:

Boch Anne-Laure,Hermelin Éric,Sainte-Rose Christian,Sgouros Spiros

Abstract

Object. The authors studied new and calcified shunt catheters to identify the prevalence of failures caused by aging materials in the shunt. Complications associated with these devices have various origins. Among late complications, fracture or migration of the system is related to the subcutaneous adhesion of the distal tubing in a growing child. A review of a cohort of 64 children who underwent shunt placement in 1980 with barium-impregnated distal catheters showed that 10 of these patients underwent reoperation for complications related to aging of the shunt material. This group represents 15% of the whole series and 30% of those children who were followed for more than 3 years. The true impact of aging of materials on shunt function is probably underestimated. Methods. The authors performed physical, chemical, and mechanical analyses of the retrieved aged catheters and also of new catheters, resulting in the following findings: 1) calcifications were observed only on the external surface of the catheter, predominantly in its subcutaneous segment at the level of the neck and anterior chest wall; 2) calcifications contained particles of free silicon and barium sulfate, signifying fragmentation of the polymer; 3) the microstructure of the silicone polymer was modified: microfractures and alteration of the polymeric network were observed; 4) silanol groups were observed on the external surface of the catheter; and 5) the mechanical properties of the silicone rubber were degraded, and the aged catheters were more brittle than the new ones, with ruptures at elongations and fracture energy much lower than that seen in new catheters. Furthermore, in vitro testing with a metastable solution of simulated body fluid demonstrated the critical impact of pH variations in liquid media and surface degradation of the catheters on the precipitation of hydroxylapatite crystals. Conclusions. Although most shunt complications can be addressed by better patient management and surgical technique, late complications appear to be partly related to aging of the material. Distal tubing calcifications have been observed in barium-impregnated catheters. The industry recently responded to these observations by introducing plain silicone-coated shunt tubing; further evaluation will show what improvement can be expected.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3