Improvement in clinical outcomes following optimal targeting of brain ventricular catheters with intraoperative imaging

Author:

Janson Christopher G.12,Romanova Liudmila G.3,Rudser Kyle D.4,Haines Stephen J.1

Affiliation:

1. Departments of Neurosurgery,

2. Neurology,

3. Medicine, and

4. Biostatistics, University of Minnesota School of Medicine, Minneapolis, Minnesota

Abstract

Object The accurate placement of cerebral ventricular shunt catheters in hydrocephalus is an important clinical problem. Malfunction of shunts remains their most common complication and greatest liability, and the influence of catheter position on shunt function remains poorly defined. The objectives of this study were as follows: 1) determine the accuracy of intraventricular catheter placement with respect to a historically favored target, defined as a 1-cm radius sphere at the anterior lip of the ipsilateral foramen of Monro; 2) confirm that this target represents a satisfactory site for frontal and occipital catheter placement by examining whether inaccuracy is associated with more shunt failures; and 3) determine whether catheter trajectory, use of image confirmation, or other factors are associated with either the accuracy or the longevity of shunts. Methods A retrospective cohort analysis was conducted on 236 patients with 426 ventricular shunts placed or revised at the University of Minnesota over a 10-year period. Results Accuracy of shunt placement was optimal in 43.9% of patients and suboptimal or poor in 56.1% of patients. Time to failure was significantly affected by the accuracy of catheter placement with respect to the ipsilateral foramen of Monro, with a 57% higher risk of failure with suboptimal placement (hazard ratio [HR] 1.57, 95% CI 1.26–1.96; p < 0.001) and a 66% higher risk with poor placement (HR 1.66, 95% CI 1.45–1.89; p < 0.001) relative to optimal placement. The odds of highly suboptimal or unacceptable placement were significantly increased by lack of any intraoperative imaging (OR 5.89, 95% CI 2.36–14.65; p < 0.001). Use of a nonfrontal posterior trajectory also showed a trend toward poor placement (OR 1.64, p = 0.138). Conclusions The historical target for catheter tip placement within 1 cm of the foramen of Monro in the ipsilateral lateral ventricle was associated with significantly longer revision-free survival compared with other locations. This effect remained significant after adjusting for age and whether there was a prior history of shunting. The accuracy of catheter placement in both pediatric and adult patients was strongly associated with use of intraoperative fluoroscopic confirmation. In analyses comparing intraoperative fluoroscopy and no imaging, there was a non–statistically significant difference in the 3-year time to failure, but the worst-case scenario of catastrophic short-term failure was almost completely avoided with fluoroscopy. The authors conclude that accuracy of placement is critical for shunt survival, and that use of intraoperative imaging confirmation may optimize outcomes by avoiding the majority of unacceptable placements.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

Cited by 43 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3