Occipitotemporal hippocampal depth electrodes in intracranial epilepsy monitoring: safety and utility

Author:

Bekelis Kimon1,Desai Atman1,Kotlyar Alex2,Thadani Vijay32,Jobst Barbara C.32,Bujarski Krzysztof32,Darcey Terrance M.132,Roberts David W.132

Affiliation:

1. Section of Neurosurgery and

2. Dartmouth Medical School, Hanover, New Hampshire

3. Department of Neurology, Dartmouth-Hitchcock Medical Center; and

Abstract

Object Intracranial monitoring for epilepsy has been proven to enhance diagnostic accuracy and provide localizing information for surgical treatment of intractable seizures. The authors investigated the usefulness of hippocampal depth electrodes in the era of more advanced imaging techniques. Methods Between 1988 and 2010, 100 patients underwent occipitotemporal hippocampal depth electrode (OHDE) implantation as part of invasive seizure monitoring, and their charts were retrospectively reviewed. The authors' technique involved the stereotactically guided (using the Leksell model G frame) implantation of a 12-contact depth electrode directed along the long axis of the hippocampus, through an occipital twist drill hole. Results Of the 100 patients (mean age 35.0 years [range 13–58 years], 51% male) who underwent intracranial investigation, 84 underwent resection of the seizure focus. Magnetic resonance imaging revealed mesial temporal sclerosis (MTS) in 27% of patients, showed abnormal findings without MTS in 55% of patients, and showed normal findings in 18% of patients. One patient developed a small asymptomatic occipital hemorrhage around the electrode tract. The use of OHDEs enabled epilepsy resection in 45.7% of patients who eventually underwent standard or selective temporal lobe resection. The hippocampal formation was spared during surgery because data obtained from the depth electrodes showed no or only secondary involvement in 14% of patients with preoperative temporal localization. The use of OHDEs prevented resections in 12% of patients with radiographic evidence of MTS. Eighty-three percent of patients who underwent resection had Engel Class I (68%) or II (15%) outcome at 2 years of follow-up. Conclusions The use of OHDEs for intracranial epilepsy monitoring has a favorable risk profile, and in the authors' experience it proved to be a valuable component of intracranial investigation. The use of OHDEs can provide the sole evidence for resection of some epileptogenic foci and can also result in hippocampal sparing or prevent likely unsuccessful resection in other patients.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3