Affiliation:
1. Departments of Neurosurgery and
2. Pediatric Surgery, Children’s Medical Center, Tehran University of Medical Sciences, Tehran, Iran
Abstract
OBJECTIVEDistal catheter malfunction due to pseudocyst formation or intraabdominal adhesion is a significant problem, especially in pediatric patients who have limited sites for distal catheter insertion. In this study, the authors present a series of 12 patients with intractable distal shunt malfunctions due to peritoneal pseudocyst formation who underwent distal catheter replacement in the suprahepatic space to reduce the risk of distal catheter malfunction.METHODSTwelve consecutive patients with shunt malfunction due to pseudocyst formation who had undergone ventriculosuprahepatic shunting from 2014 to 2019 were identified. According to medical records, after primary evaluations, shunt removal, and antibiotic therapy, they underwent revision surgeries with placement of a distal catheter into the suprahepatic space.RESULTSNine boys and 3 girls, ranging in age from 5 months to 14 years, with one or more episodes of pseudocyst formation, underwent shunt revision with placement of a distal catheter into the suprahepatic space. After a median follow-up of 31 months, none of the patients experienced further distal malfunction.CONCLUSIONSThe suprahepatic space appears to be a safe place to secure the distal end of a ventricular catheter following pseudocyst formation, with less risk of re-adhesion. This lower risk might be attributable to the lack of omentum in the suprahepatic space.
Publisher
Journal of Neurosurgery Publishing Group (JNSPG)
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献