Changes in adjacent-level disc pressure and facet joint force after cervical arthroplasty compared with cervical discectomy and fusion

Author:

Chang Ung-Kyu1,Kim Daniel H.2,Lee Max C.3,Willenberg Rafer4,Kim Se-Hoon5,Lim Jesse5

Affiliation:

1. Department of Neurosurgery, Korea Institute of Radiological and Medical Sciences, Seoul, Korea;

2. Department of Neurosurgery, Ochsner Clinic Foundation, New Orleans, Louisiana;

3. Milwaukee Neurological Institute, Milwaukee, Wisconsin;

4. Stanford University Medical School, and

5. Department of Neurosurgery, Stanford University Medical Center, Stanford, California

Abstract

Object The authors of previous in vitro investigations have reported an increase in adjacent-level intradiscal pressures (IDPs) and facet joint stresses following cervical spine fusion. This study was performed to compare adjacent-level IDPs and facet force following arthroplasty with the fusion model. Methods Eighteen human cadaveric cervical spines were tested in the intact state for different modes of motion (extension, flexion, bending, and rotation) up to 2 Nm. The specimens were then divided into three groups: those involving the ProDisc-C cervical artificial disc, Prestige cervical artificial disc, and cervical fusion. They were load tested after application of instrumentation or surgery at the C6–7 level. During the test, IDPs and facet forces were measured at adjacent levels. Results In arthroplasty-treated specimens, the IDP showed little difference from that of the intact spine at both proximal and distal levels. In fusion-treated specimens, the IDP increased at the posterior anulus fibrosus on extension and at the anterior anulus fibrosus on flexion at the proximal level. At the distal level, the IDP change was not significant. The facet force changes were minimal in flexion, bending, and rotation modes in both arthroplasty- and fusion-treated spines. Significant changes were noted in the extension mode only. In extension, arthroplasty models exhibited significant increases of facet force at the treated level. In the fusion model the facet forces decreased at the treated segment and increased at the adjacent segment. Conclusions The two artificial discs of the semiconstrained systems maintain adjacent-level IDPs near the preoperative values in all modes of motion, but with respect to facet force pressure tended to increase after arthroplasty.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3