Comparing indocyanine green videoangiography to the gold standard of intraoperative digital subtraction angiography used in aneurysm surgery

Author:

Washington Chad W.1,Zipfel Gregory J.12,Chicoine Michael R.1,Derdeyn Colin P.123,Rich Keith M.13,Moran Christopher J.13,Cross DeWitte T.13,Dacey Ralph G.1

Affiliation:

1. Departments of Neurological Surgery,

2. Neurology, and

3. Radiology, Washington University Center for Stroke and Cerebrovascular Disease, Washington University School of Medicine, St. Louis, Missouri

Abstract

Object The purpose of aneurysm surgery is complete aneurysm obliteration while sparing associated arteries. Indocyanine green (ICG) videoangiography is a new technique that allows for real-time evaluation of blood flow in the aneurysm and vessels. The authors performed a retrospective study to compare the accuracy of ICG videoangiography with intraoperative angiography (IA), and determine if ICG videoangiography can be used without follow-up IA. Methods From June 2007 through September 2009, 155 patients underwent craniotomies for clipping of aneurysms. Operative summaries, angiograms, and operative and ICG videoangiography videos were reviewed. The number, size, and location of aneurysms, the ICG videoangiography and IA findings, and the need for clip adjustment after ICG videoangiography and IA were recorded. Discordance between ICG videoangiography and IA was defined as ICG videoangiography demonstrating aneurysm obliteration and normal vessel flow, but post-IA showing either an aneurysmal remnant and/or vessel occlusion requiring clip adjustment. Results Thirty-two percent of patients (49 of 155) underwent both ICG videoangiography and IA. The post-ICG videoangiography clip adjustment rate was 4.1% (2 of 49). The overall rate of ICG videoangiography–IA agreement was 75.5% (37 of 49) and the ICG videoangiography–IA discordance rate requiring post-IA clip adjustment was 14.3% (7 of 49). Adjustments were due to 3 aneurysmal remnants and 4 vessel occlusions. These adjustments were attributed to obscuration of the residual aneurysm or the affected vessel from the field of view and the presence of dye in the affected vessel via collateral flow. Although not statistically significant, there was a trend for ICG videoangiography–IA discordance requiring clip adjustment to occur in cases involving the anterior communicating artery complex, with an odds ratio of 3.3 for ICG videoangiography–IA discordance in these cases. Conclusions These results suggest that care should be taken when considering ICG videoangiography as the sole means for intraoperative evaluation of aneurysm clip application. The authors further conclude that IA should remain the gold standard for evaluation during aneurysm surgery. However, a combination of ICG videoangiography and IA may ultimately prove to be the most effective strategy for maximizing the safety and efficacy of aneurysm surgery.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3