Diagnostic and therapeutic values of intraoperative electrophysiological neuromonitoring during resection of intradural extramedullary spinal tumors: a single-center retrospective cohort and meta-analysis

Author:

Ishida Wataru1,Casaos Joshua1,Chandra Arun1,D’Sa Adam1,Ramhmdani Seba1,Perdomo-Pantoja Alexander1,Theodore Nicholas1,Jallo George12,Gokaslan Ziya L.3,Wolinsky Jean-Paul4,Sciubba Daniel M.1,Bydon Ali1,Witham Timothy F.1,Lo Sheng-Fu L.1

Affiliation:

1. Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland;

2. Department of Neurosurgery, Johns Hopkins All Children’s Hospital, St. Petersburg, Florida

3. Department of Neurosurgery, Brown University School of Medicine, Providence, Rhode Island;

4. Department of Neurological Surgery, Northwestern University, Chicago, Illinois; and

Abstract

OBJECTIVEWith the advent of intraoperative electrophysiological neuromonitoring (IONM), surgical outcomes of various neurosurgical pathologies, such as brain tumors and spinal deformities, have improved. However, its diagnostic and therapeutic value in resecting intradural extramedullary (ID-EM) spinal tumors has not been well documented in the literature. The objective of this study was to summarize the clinical results of IONM in patients with ID-EM spinal tumors.METHODSA retrospective patient database review identified 103 patients with ID-EM spinal tumors who underwent tumor resection with IONM (motor evoked potentials, somatosensory evoked potentials, and free-running electromyography) from January 2010 to December 2015. Patients were classified as those without any new neurological deficits at the 6-month follow-up (group A; n = 86) and those with new deficits (group B; n = 17). Baseline characteristics, clinical outcomes, and IONM findings were collected and statistically analyzed. In addition, a meta-analysis in compliance with the PRISMA guidelines was performed to estimate the overall pooled diagnostic accuracy of IONM in ID-EM spinal tumor resection.RESULTSNo intergroup differences were discovered between the groups regarding baseline characteristics and operative data. In multivariate analysis, significant IONM changes (p < 0.001) and tumor location (thoracic vs others, p = 0.018) were associated with new neurological deficits at the 6-month follow-up. In predicting these changes, IONM yielded a sensitivity of 82.4% (14/17), specificity of 90.7% (78/86), positive predictive value (PPV) of 63.6% (14/22), negative predictive value (NPV) of 96.3% (78/81), and area under the curve (AUC) of 0.893. The diagnostic value slightly decreased in patients with schwannomas (AUC = 0.875) and thoracic tumors (AUC = 0.842). Among 81 patients who did not demonstrate significant IONM changes at the end of surgery, 19 patients (23.5%) exhibited temporary intraoperative exacerbation of IONM signals, which were recovered by interruption of surgical maneuvers; none of these patients developed new neurological deficits postoperatively. Including the present study, 5 articles encompassing 323 patients were eligible for this meta-analysis, and the overall pooled diagnostic value of IONM was a sensitivity of 77.9%, a specificity of 91.1%, PPV of 56.7%, and NPV of 95.7%.CONCLUSIONSIONM for the resection of ID-EM spinal tumors is a reasonable modality to predict new postoperative neurological deficits at the 6-month follow-up. Future prospective studies are warranted to further elucidate its diagnostic and therapeutic utility.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3