Anatomical and technical factors associated with superior facet joint violation in lumbar fusion

Author:

Teles Alisson R.12,Paci Michael3,Gutman Gabriel12,Abduljabbar Fahad H.145,Ouellet Jean A.14,Weber Michael H.14,Golan Jeff D.132

Affiliation:

1. McGill Scoliosis and Spine Group, McGill University Health Centre;

2. Department of Neurosciences, Jewish General Hospital, Montreal, Quebec, Canada; and

3. Neurosurgery, McGill University;

4. Departments of Orthopedic Surgery and

5. Department of Orthopedic Surgery, King Abdulaziz University, Jeddah, Saudi Arabia

Abstract

OBJECTIVEThe aim of this study was to evaluate the anatomical and surgical risk factors for screw-related facet joint violation at the superior level in lumbar fusion.METHODSThe authors conducted a retrospective review of a consecutive series of posterior lumbar instrumented fusions performed by a single surgeon. Inclusion criteria were primary lumbar fusion of 1 or 2 levels for degenerative disorders. The following variables were analyzed as possible risk factors: surgical technique (percutaneous vs open screw placement), depth of surgical field, degree of anterior slippage of the superior level, pedicle and facet angle, and facet degeneration of the superior level. Postoperative CT scans were evaluated by 2 independent reviewers. Axial, sagittal, and coronal views were reviewed. Pedicle screws were graded as intra-articular if they clearly interposed between the superior and inferior facet joints of the superior level. Multivariate logistic regression analyses were conducted to assess the factors associated with this complication.RESULTSOne hundred thirty-one patients were included. Interobserver reliability for facet joint violation assessment was high (κ = 0.789). The incidence of superior facet joint violation was 12.59% per top-level screw (33 of 262 proximal screws). The rate of facet violation was 28.0% in the percutaneous technique group (14 of 50 patients) and 12.3% in the open surgery group (10 of 81 patients) (OR 2.26, 95% CI 1.09–4.21; p = 0.024). In multivariate logistic regression analysis, independent predictors of facet violation were percutaneous screw placement (adjusted OR 3.31, 95% CI 1.42–7.73; p = 0.006), right-side pedicle screw (adjusted OR 3.14, 95% CI 1.29–7.63; p = 0.011), and facet angle > 45° (adjusted OR 10.95, 95% CI 4.64–25.84; p < 0.0001).CONCLUSIONSThe incidence of facet joint violation was higher in percutaneous minimally invasive than in open technique for posterior lumbar spine surgery. Also, coronal orientation of the facet joint is a significant risk factor independent of the surgical technique.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3