Affiliation:
1. Department of Neurosurgery,
2. TUM-Neuroimaging Center, and
3. Department of Diagnostic and Interventional Neuroradiology, Klinikum rechts der Isar, Technische Universität München, Munich, Germany
Abstract
OBJECTIVESemi-rigid instrumentation (SRI) was introduced to take advantage of the concept of load sharing in surgery for spinal stabilization. The authors investigated a topping-off technique in which interbody fusion is not performed in the uppermost motion segment, thus creating a smooth transition from stabilized to free motion segments. SRI using the topping-off technique also reduces the motion of the adjacent segments, which may reduce the risk of adjacent segment disease (ASD), a frequently observed sequela of instrumentation and fusion, but this technique may also increase the possibility of screw loosening (SL). In the present study the authors aimed to systematically evaluate reoperation rates, clinical outcomes, and potential risk factors and incidences of ASD and SL for this novel approach.METHODSThe authors collected data for the first 322 patients enrolled at their institution from 2009 to 2015 who underwent surgery performed using the topping-off technique. Reoperation rates, patient satisfaction, and other outcome measures were evaluated. All patients underwent pedicle screw–based semi-rigid stabilization of the lumbar spine with a polyetheretherketone (PEEK) rod system.RESULTSImplantation of PEEK rods during revision surgery was performed in 59.9% of patients. A median of 3 motion segments (range 1–5 segments) were included and a median of 2 motion segments (range 0–4 segments) were fused. A total of 89.4% of patients underwent fusion, 73.3% by transforaminal lumbar interbody fusion (TLIF), 18.4% by anterior lumbar interbody fusion (ALIF), 3.1% by extreme lateral interbody fusion (XLIF), 0.3% by oblique lumbar interbody fusion (OLIF), and 4.9% by combined approaches in the same surgery. Combined radicular and lumbar pain according to a visual analog scale was reduced from 7.9 ± 1.0 to 4.0 ± 3.1, with 56.2% of patients indicating benefit from surgery. After maximum follow-up (4.3 ± 1.8 years), the reoperation rate was 16.4%.CONCLUSIONSThe PEEK rod concept including the topping-off principle seems safe, with at least average patient satisfaction in this patient group. Considering the low rate of first-tier surgeries, the presented results seem at least comparable to those of most other series. Follow-up studies are needed to determine long-term outcomes, particularly with respect to ASD, which might be reduced by the presented approach.
Publisher
Journal of Neurosurgery Publishing Group (JNSPG)
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献