Percutaneous transluminal angioplasty for intracranial atherosclerotic lesions: evolution of technique and short-term results

Author:

Connors J. J.,Wojak Joan C.

Abstract

Object. A retrospective analysis of a 9-year experience with balloon angioplasty for intracranial atherosclerotic stenosis was undertaken with the goals of illustrating development of a safe technique for treatment of intracranial atherosclerotic disease and reporting the immediate results in this series of patients.Methods. Three distinct periods are defined, based on the technique used. In the early period, in which eight patients were treated, the angioplasty balloon size approximated the vessel size, but was always smaller. Angioplasty was moderately rapid and brief (15–30 seconds). Clinical improvement occurred in seven (87.5%) of eight patients, dissection without consequence occurred in four (50%) of eight, and residual stenosis greater than 50% was found in three (37.5%) of eight. No neurological complications occurred.In the middle period, in which 12 patients were treated, the balloon size approximated the vessel size, but oversizing by up to 0.25 mm was permitted. Angioplasty was extremely rapid and brief. Angiographically visible dissection occurred in nine (75%) of 12 patients, necessitating urokinase infusion in five (41.7%) of 12 and producing abrupt occlusion in one (8.3%) of 12, resulting in death. Occlusion secondary to the recrossing of the lesion occurred in one (8.3%) of 12, resulting in stroke. Good outcome was eventually achieved in 10 (83.3%) of 12.In the current period, in which 50 patients have been treated, the balloon is always undersized and inflation is extremely slow (several minutes). Dissection occurred in seven (14%) of 50 patients, necessitating fibrinolysis in two of 50 (4%, both uneventful) and producing no abrupt occlusion or stroke. Residual stenosis greater than 50% occurred in eight (16%) of 50, with no stenosis greater than 70%. Late restenosis occurred in four (9%) of 44 and successful repeated angioplasty was performed in all four. One guidewire vessel perforation occurred (2%), resulting in the patient's death. Good angiographic and short-term clinical outcome was achieved in the other 49 patients (98%).Conclusions. Extremely slow balloon inflation combined with balloon undersizing results in decreased intimal damage, decreased acute platelet/thrombus deposition, and decreased acute closure. This technique sometimes yields suboptimal angiographic results but achieves the clinical goal safely. Intracranial angioplasty can be safely performed using this technique and modern equipment.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3