Robot-assisted endoscopic third ventriculostomy: institutional experience in 9 patients

Author:

Hoshide Reid,Calayag Mark,Meltzer Hal,Levy Michael L.,Gonda David

Abstract

OBJECTIVEThe endoscopic third ventriculostomy (ETV) is an established and effective treatment for obstructive hydrocephalus. In its most common application, surgeons plan their entry point and the endoscope trajectory for the procedure based on anatomical landmarks, then control the endoscope freehand. Recent studies report an incidence of neural injuries as high as 16.6% of all ETVs performed in North America. The authors have introduced the ROSA system to their ETV procedure to stereotactically optimize endoscope trajectories, to reduce risk of traction on neural structures by the endoscope, and to provide a stable mechanical holder of the endoscope. Here, they present their series in which the ROSA system was used for ETVs.METHODSAt the authors’ institution, they performed ETVs with the ROSA system in 9 consecutive patients within an 8-month period. Patients had to have a favorable expected response to ETV (ETV Success Score ≥ 70) with no additional endoscopic procedures (e.g., choroid plexus cauterization, septum pellucidum fenestration). The modality of image registration (CT, MRI, surface mapping, or bone fiducials) was dependent on the case.RESULTSNine pediatric patients with an age range of 1.5 to 16 years, 4 girls and 5 boys, with ETV Success Scores ranging from 70 to 90, underwent successful ETV surgery with the ROSA system within an 8-month period. Their intracranial pathologies included tectal tumors (n = 3), communicating hydrocephalus from hemorrhage or meningeal disease (n = 2), congenital aqueductal stenosis (n = 1), compressive porencephalic cyst (n = 1), Chiari I malformation (n = 1), and pineal region mass (n = 1). Robotic assistance was limited to the ventricular access in the first 2 procedures, but was used for the entirety of the procedure for the following 7 cases. Four of these cases were combined with another procedural objective (3 stereotactic tectal mass biopsies, 1 Chiari decompression). A learning curve was observed with each subsequent surgery as registration and surgical times became shorter and more efficient. All patients had complete resolution of their preprocedural symptoms. There were no complications.CONCLUSIONSThe ROSA system provides a stable, precise, and minimally invasive approach to ETVs.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

Cited by 28 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3