Multislice computerized tomography angiography in the evaluation of intracranial aneurysms: a comparison with intraarterial digital subtraction angiography

Author:

Wintermark Max,Uske Antoine,Chalaron Marc,Regli Luca,Maeder Philippe,Meuli Reto,Schnyder Pierre,Binaghi Stefano

Abstract

Object. The goal of this study was to assess the diagnostic accuracy of computerized tomography (CT) angiography performed with the aid of multislice technology (MSCT angiography) in the investigation of intracranial aneurysms, by comparing this method with intraarterial digital subtraction (IADS) angiography. Methods. Fifty consecutive adult patients, who successively underwent MSCT angiography (four rows) and IADS angiography of intracranial vessels, were prospectively identified. The MSCT angiography studies consisted of 1.25-mm slices, with 0.8-mm reconstruction intervals, a pitch of 0.75, and timing determined by a test bolus. Two neuroradiologists, who were blinded to the initial interpretation of the MSCT angiograms as well as to those of the IADS angiograms, independently reviewed the MSCT angiograms for the detection and characterization of intracranial aneurysms. Forty-nine intracranial aneurysms were identified in 40 patients; 33 of these lesions were responsible for subarachnoid hemorrhage. The sensitivity, specificity, and accuracy of MSCT angiography in the detection of intracranial aneurysms were 94.8, 95.2, and 94.9%, respectively, on a per-aneurysm basis and 99, 95.2, and 98.3%, respectively, on a per-patient basis. Interobserver agreement was 98%. There was an excellent correlation between aneurysm size assessed using MSCT angiography and that determined by IADS angiography (slope = 0.916, r = 0.877, p < 0.001); however, 2 mm stood as the cutoff size below which the sensitivity of MSCT angiography was statistically lower. That method displayed great accuracy in characterizing the morphological characteristics of the aneurysm. Conclusions. Multislice CT angiography is an accurate and robust noninvasive screening test for intracranial aneurysms. It performs better than that reported for single-slice CT angiography. Introduction of eight- and especially 16-row MSCT angiography will provide further progression through thinner slices, a lower pitch, and a purely arterial phase.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Cited by 154 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3