Noninvasive intracranial compliance monitoring

Author:

Lang Erhard W.,Paulat Klaus,Witte Christoph,Zolondz Jürgen,Mehdorn H. Maximilian

Abstract

✓ Although invasive measurement of intracranial pressure (ICP) involving high-resolution waveform analysis allows assessment of intracranial compliance (ICC), it is only feasible in a few selected neurosurgical conditions. Intracranial compliance can be assessed using the high-frequency centroid (HFC), which is the power-weighted mean frequency within the 4 to 15—Hz band of the ICP waveform. The authors have systematically tested the utility, performance, and reliability of a noninvasive monitor of ICC. The underlying principle of this device is that the ICP transmission and its infrasonic waves are transmitted through the inner ear toward the tympanic membrane. If the outer ear is sealed in an airtight fashion, motions of the tympanic membrane cause air pressure fluctuations that can be recorded using a special sensor. The authors compared the HFC calculated from an intraparenchymal ICP sensor with that obtained simultaneously from an ipsilaterally placed noninvasive device during half of a respiratory cycle (peak to baseline) as well as for three random samples of three heart cycles. They analyzed 32 sessions in 13 patients in whom mechanical ventilation had been established. In four (11%) of 36 sessions they could not demonstrate an adequate signal. For the peak-to-baseline cycle, the mean invasively recorded HFC was 8.05 ± 0.55 Hz (range 6.7–9 Hz) whereas the mean noninvasively recorded HFC was 8.04 ± 0.49 Hz (range 7–9.3 Hz). The ICP was 8.5 ± 5 mm Hg (range 2–24 mm Hg). For the three heart cycles randomly sampled, the values were 7.73 ± 0.51 Hz (range 6.7–8.6 Hz) and 7.76 ± 0.56 mm Hg (range 6.5–8.8 mm Hg), respectively. This device allows noninvasive assessment of ICC based on the HFC waveform analysis that is equivalent to that obtained by invasive intraparenchymal recording. The monitoring device may become a valuable tool for monitoring parameters in patients in whom placement of an intracranial sensor is not feasible but assessment of ICC as an alternative to ICP measurement is desired.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3